Trane / AIR-SOURCE HEAT PUMP

5TWX6024A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 3

93 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5TWX6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1793 / 93
EER2 · BTU/Wh11.7–1293 / 93
HSPF2 · BTU/Wh7.8–8.193 / 93
Cooling capacity · BTU/h23,200–24,80093 / 93
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,00093 / 93
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,00093 / 93
Heating capacity at 5°F / −15°C · BTU/h11,000–11,50093 / 93
COP at 5°F / −15°C2.12–2.2893 / 93
Equipment / loop typeHP - Split System93 / 93
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)93 / 93
Compressor stagingSingle stage93 / 93
Connected capabilityNo93 / 93

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21810978416.008.00113002.16EPA 4575084
5PX*B006AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21810978316.008.00113002.16EPA 4575085
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21810978216.008.00113002.17EPA 4575086
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21810978016.008.00115002.15EPA 4575087
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21810977916.008.00115002.15EPA 4575088
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810977816.008.00113002.17EPA 4575089
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21810977116.008.00112002.19EPA 4575090
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810977016.008.00113002.17EPA 4575091
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810976916.008.00114002.15EPA 4575092
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810976816.008.00114002.15EPA 4575093
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810976516.007.80112002.21EPA 4575094
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21810976416.008.00115002.14EPA 4575095
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21811236716.008.10113002.16EPA 4575577
5TXCB006AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21811236616.008.10113002.17EPA 4575578
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21811236516.008.10113002.18EPA 4575579
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21811236316.008.10113002.18EPA 4575580
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21811236216.008.10113002.16EPA 4575581
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21811235916.008.10113002.16EPA 4575584
5TXCB006AS3+TSTAT+ furnace: S8X1B040M2PSCAHRI reference: 21811235816.008.10113002.16EPA 4575585
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21811235716.008.10113002.16EPA 4575586

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →