9 published source records · source checked Sep 21, 2026

SEER2 range17.5–18BTU/Wh
HSPF2 range8.5–8.7BTU/Wh
Cooling capacity37,400–38,000BTU/h

Each efficiency range summarizes published EPA records for 4TWL9036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 9 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–189 / 9
EER2 · BTU/Wh11.7–129 / 9
HSPF2 · BTU/Wh8.5–8.79 / 9
Cooling capacity · BTU/h37,400–38,0009 / 9
Heating capacity at 47°F / 8.3°C · BTU/h33,200–33,6009 / 9
Heating capacity at 17°F / −8.3°C · BTU/h23,200–23,6009 / 9
Equipment / loop typeHP - Split System9 / 9
Refrigerant / source-reported GWPR-410A (GWP:2088)9 / 9
Compressor stagingContinuously variable9 / 9
Connected capabilityNo9 / 9

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhRecord & comparison
4TXCD010DS3+ furnace: S8V2D120M5PCAAHRI reference: 21069175418.008.70EPA 2472534
4PX*DU60BS3+ furnace: S8V2D120M5PCAAHRI reference: 21069174018.008.70EPA 2472543
4PX*CU60BS3+ furnace: S8V2C080M5PCAAHRI reference: 21069173617.508.70EPA 2472227
4TXCD008DS3+ furnace: S8V2D120M5PCAAHRI reference: 21069175317.508.70EPA 2472333
4TXCC009DS3+ furnace: S8V2C100M5PCAAHRI reference: 21069175217.508.70EPA 2472446
4PX*DU48BS3+ furnace: S8V2D120M5PCAAHRI reference: 21069173917.508.70EPA 2472533
4PX*CU60BS3+ furnace: S8V2C100M5PCAAHRI reference: 21069173717.508.70EPA 2472535
4TXCC009DS3+ furnace: S8V2C080M5PCAAHRI reference: 21069175117.508.70EPA 2472537
4PX*CD60BS3+ furnace: S8V2C100M5PCAAHRI reference: 21069172917.508.50EPA 2472542

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.