Trane / AIR-SOURCE HEAT PUMP

5TWX6024A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 2

93 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5TWX6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1793 / 93
EER2 · BTU/Wh11.7–1293 / 93
HSPF2 · BTU/Wh7.8–8.193 / 93
Cooling capacity · BTU/h23,200–24,80093 / 93
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,00093 / 93
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,00093 / 93
Heating capacity at 5°F / −15°C · BTU/h11,000–11,50093 / 93
COP at 5°F / −15°C2.12–2.2893 / 93
Equipment / loop typeHP - Split System93 / 93
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)93 / 93
Compressor stagingSingle stage93 / 93
Connected capabilityNo93 / 93

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21810995516.008.10115002.15EPA 4575053 →
5TEMCD05AV41+TDR+TSTATAHRI reference: 21810987516.008.10111002.24EPA 4575056 →
5TEMCD04AV31+TDR+TSTATAHRI reference: 21810987416.008.10111002.24EPA 4575057 →
5TEM6D05AV41+TDR+TSTATAHRI reference: 21810987116.008.10112002.21EPA 4575060 →
5TAMXD04AV31+TSTATAHRI reference: 21810986216.008.00112002.15EPA 4575066 →
5PX*CD07AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21810985616.008.00114002.13EPA 4575067 →
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810985316.008.00113002.20EPA 4575069 →
5PX*C005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810985116.008.00112002.14EPA 4575070 →
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810985016.008.00112002.15EPA 4575071 →
5PX*BD06AS3+TSTAT+ furnace: S9X2B060D3PSBAHRI reference: 21810984916.008.00112002.16EPA 4575072 →
5PX*BD06AS3+TSTAT+ furnace: S9X1B080D4PSBAHRI reference: 21810984716.008.00113002.16EPA 4575073 →
5PX*BD06AS3+TSTAT+ furnace: S9X1B060D3PSBAHRI reference: 21810984616.008.00112002.16EPA 4575074 →
5PX*BD06AS3+TSTAT+ furnace: S9V2B080D4VSBAHRI reference: 21810984416.008.00112002.15EPA 4575075 →
5PX*BD06AS3+TSTAT+ furnace: S9V2B060D3VSBAHRI reference: 21810984316.008.00112002.15EPA 4575076 →
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810984016.007.80112002.15EPA 4575077 →
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21810983916.007.80112002.15EPA 4575078 →
5PX*BD06AS3+TSTAT+ furnace: *DHMB080CCV3AHRI reference: 21810983716.007.80112002.15EPA 4575080 →
5PX*BD06AS3+TSTAT+ furnace: S9X2B080D4PSBAHRI reference: 21810983616.008.00113002.16EPA 4575081 →
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810982916.008.00111002.16EPA 4575082 →
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810982816.008.00111002.16EPA 4575083 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →