Trane / AIR-SOURCE HEAT PUMP

5TWX6024A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 4

93 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5TWX6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1793 / 93
EER2 · BTU/Wh11.7–1293 / 93
HSPF2 · BTU/Wh7.8–8.193 / 93
Cooling capacity · BTU/h23,200–24,80093 / 93
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,00093 / 93
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,00093 / 93
Heating capacity at 5°F / −15°C · BTU/h11,000–11,50093 / 93
COP at 5°F / −15°C2.12–2.2893 / 93
Equipment / loop typeHP - Split System93 / 93
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)93 / 93
Compressor stagingSingle stage93 / 93
Connected capabilityNo93 / 93

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X1B040M2PTCAHRI reference: 21811235616.008.10113002.16EPA 4575587
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21811235516.008.10113002.16EPA 4575588
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21811230516.008.10113002.18EPA 4575597
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21811229616.008.10113002.18EPA 4575598
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21815931316.007.80114002.16EPA 4576610
5TEM6D04AV31+TDR+TSTATAHRI reference: 21815930516.008.10112002.22EPA 4576611
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21815930316.008.00112002.15EPA 4576612
5PX*BD06AS3+TSTAT+ furnace: *DHMB060CCV3AHRI reference: 21815930216.008.00114002.13EPA 4576613
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21815930116.007.80110002.18EPA 4576614
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3VSBAHRI reference: 21815930016.008.00111002.15EPA 4576615
5TXCC005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810997815.207.80112002.14EPA 4575033
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810997715.207.80114002.15EPA 4575034
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21810997315.208.10113002.17EPA 4575036
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810997015.207.80112002.21EPA 4575039
5TXCB006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21810996915.207.80113002.16EPA 4575040
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21810996815.207.80115002.14EPA 4575041
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21810996715.207.80114002.16EPA 4575042
5TXCB006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21810996615.207.80114002.14EPA 4575043
5TXCB006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21810996515.208.10111002.20EPA 4575044
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810996115.207.80113002.17EPA 4575047

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →