Trane / AIR-SOURCE HEAT PUMP

5TWX6024A1

16 Single-Stage Heat Pump with WeatherGuard Top

93 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5TWX6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1793 / 93
EER2 · BTU/Wh11.7–1293 / 93
HSPF2 · BTU/Wh7.8–8.193 / 93
Cooling capacity · BTU/h23,200–24,80093 / 93
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,00093 / 93
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,00093 / 93
Heating capacity at 5°F / −15°C · BTU/h11,000–11,50093 / 93
COP at 5°F / −15°C2.12–2.2893 / 93
Equipment / loop typeHP - Split System93 / 93
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)93 / 93
Compressor stagingSingle stage93 / 93
Connected capabilityNo93 / 93

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TEMCD07AV51+TDR+TSTATAHRI reference: 21810987717.007.80110002.28EPA 4575054 →
5TEMCD06AV41+TDR+TSTATAHRI reference: 21810987617.008.00110002.26EPA 4575055 →
5TAMXD05AV41+TSTATAHRI reference: 21810986316.508.00112002.18EPA 4575065 →
5PX*C009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810985416.508.00112002.20EPA 4575068 →
5PX*BD06AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21811234516.508.10113002.15EPA 4575589 →
5PX*BD06AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21811234416.508.10113002.15EPA 4575590 →
5PX*BD06AS3+TSTAT+ furnace: S8X1B040M2PSCAHRI reference: 21811234216.508.10112002.14EPA 4575592 →
5PX*BD06AS3+TSTAT+ furnace: S8X1B040M2PTCAHRI reference: 21811234116.508.10112002.14EPA 4575593 →
5PX*BD06AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21811233916.508.10113002.15EPA 4575595 →
5PX*BD06AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21811233816.508.10113002.15EPA 4575596 →
5TXCC009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21815931516.508.00112002.20EPA 4576609 →
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810998016.008.10113002.20EPA 4575032 →
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21810997416.007.80114002.16EPA 4575035 →
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21810997216.008.10113002.17EPA 4575037 →
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21810997116.008.10115002.15EPA 4575038 →
5TXCB006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21810996416.007.80112002.19EPA 4575045 →
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810996316.007.80114002.16EPA 4575046 →
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810995816.007.80113002.17EPA 4575050 →
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21810995716.007.80113002.17EPA 4575051 →
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21810995616.007.80114002.16EPA 4575052 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →