Trane / AIR-SOURCE HEAT PUMP

5TWX5048A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 3

101 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 101 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16101 / 101
EER2 · BTU/Wh11.7–12101 / 101
HSPF2 · BTU/Wh7.8–8.5101 / 101
Cooling capacity · BTU/h43,000–46,000101 / 101
Heating capacity at 47°F / 8.3°C · BTU/h42,000–44,000101 / 101
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,200101 / 101
Heating capacity at 5°F / −15°C · BTU/h21,400–22,600101 / 101
COP at 5°F / −15°C2–2.3101 / 101
Equipment / loop typeHP - Split System101 / 101
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)101 / 101
Compressor stagingSingle stage101 / 101
Connected capabilityNo101 / 101

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21568760615.508.10222002.10EPA 3651370
5PX*D010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21568760915.508.10222002.10EPA 3651371
5PX*D010AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21568761115.508.10218002.00EPA 3651373
5PX*D010AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21568761815.508.00218002.00EPA 3651377
5PX*D010AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21568761915.508.00218002.00EPA 3651378
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21568762515.508.10224002.10EPA 3651379
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21568762615.508.10224002.10EPA 3651380
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21568763115.508.10224002.10EPA 3651381
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21568763215.508.10224002.10EPA 3651382
5PX*D010AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21568764015.508.10218002.00EPA 3651383
5PX*DD10AS3+TSTAT+P0V0D000M50SDAHRI reference: 21568764615.508.10220002.10EPA 3651385
5PX*DD10AS3+TSTAT+P0V0C000M50SDAHRI reference: 21568764715.508.10218002.00EPA 3651386
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21568766515.508.00220002.10EPA 3651392
5PX*D010AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583172015.508.10220002.10EPA 3737750
5PX*D010AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583172115.508.10222002.10EPA 3737751
5TXCD010AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583173115.508.10220002.10EPA 3737752
5TXCD010AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583173215.508.10222002.10EPA 3737753
5TEMCD05AV41+TDR+TSTATAHRI reference: 21586398315.508.10218002.20EPA 3737783
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCAAHRI reference: 21418306815.207.80224002.00EPA 3423500
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21418307015.207.80222002.00EPA 3423501

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →