Trane / AIR-SOURCE HEAT PUMP

5TWX5048A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 4

101 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 101 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16101 / 101
EER2 · BTU/Wh11.7–12101 / 101
HSPF2 · BTU/Wh7.8–8.5101 / 101
Cooling capacity · BTU/h43,000–46,000101 / 101
Heating capacity at 47°F / 8.3°C · BTU/h42,000–44,000101 / 101
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,200101 / 101
Heating capacity at 5°F / −15°C · BTU/h21,400–22,600101 / 101
COP at 5°F / −15°C2–2.3101 / 101
Equipment / loop typeHP - Split System101 / 101
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)101 / 101
Compressor stagingSingle stage101 / 101
Connected capabilityNo101 / 101

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21418307215.207.80224002.00EPA 3423502
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21418307415.207.80222002.00EPA 3423503
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21418307615.207.80224002.00EPA 3423504
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21418308015.207.80222002.00EPA 3423505
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21418309215.207.80214002.10EPA 3423508
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21418309615.207.80214002.10EPA 3423510
5TXCD010AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21418313515.208.10218002.00EPA 3423525
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21418314715.208.10222002.10EPA 3423527
5TXCD010AS3+TSTAT+ furnace: *UHMC100ACV4AHRI reference: 21418315915.208.10220002.00EPA 3423530
5TXCD010AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21418316115.208.10220002.00EPA 3423531
5TXCD010AS3+TSTAT+ furnace: *UHMD120ACV5AHRI reference: 21418316315.208.10220002.10EPA 3423532
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDAAHRI reference: 21418303315.207.80224002.00EPA 3424406
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21418305115.207.80224002.00EPA 3424407
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21418301815.207.80222002.00EPA 3424693
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21418302015.207.80224002.00EPA 3424694
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDAAHRI reference: 21418302515.207.80224002.00EPA 3424695
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCAAHRI reference: 21418302915.207.80224002.00EPA 3424696
5TXCD010AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21418313315.208.10218002.00EPA 3549676
5TXCD010AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21418316715.208.10218002.00EPA 3549678
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21568752715.208.10224002.10EPA 3651244

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →