Trane / AIR-SOURCE HEAT PUMP

5TWX5048A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 2

101 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 101 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16101 / 101
EER2 · BTU/Wh11.7–12101 / 101
HSPF2 · BTU/Wh7.8–8.5101 / 101
Cooling capacity · BTU/h43,000–46,000101 / 101
Heating capacity at 47°F / 8.3°C · BTU/h42,000–44,000101 / 101
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,200101 / 101
Heating capacity at 5°F / −15°C · BTU/h21,400–22,600101 / 101
COP at 5°F / −15°C2–2.3101 / 101
Equipment / loop typeHP - Split System101 / 101
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)101 / 101
Compressor stagingSingle stage101 / 101
Connected capabilityNo101 / 101

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21418312115.507.80214002.10EPA 3423519
5TXCD010AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21418311815.507.80214002.10EPA 3423520
5TXCD010AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21418312315.507.80214002.10EPA 3423521
5TXCD010AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21418312515.507.80214002.10EPA 3423522
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21418312715.508.00222002.10EPA 3423523
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21418312915.508.00222002.10EPA 3423524
5TXCD010AS3+TSTAT+P0V0D000M50SDAHRI reference: 21418314515.508.00218002.20EPA 3423526
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PCAAHRI reference: 21418315315.507.80216002.00EPA 3423528
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PDAAHRI reference: 21418315715.507.80216002.00EPA 3423529
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSBAHRI reference: 21418316915.508.10220002.10EPA 3423533
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSCAHRI reference: 21418317115.508.10220002.10EPA 3423534
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSAAHRI reference: 21418317415.508.10220002.10EPA 3423535
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21418317615.508.10220002.10EPA 3423536
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21418318215.508.10220002.10EPA 3423537
5TEM6D06AV41+TDR+TSTATAHRI reference: 21418295715.508.10226002.20EPA 3424691
5TEM6D07AV51+TDR+TSTATAHRI reference: 21418295915.508.50226002.20EPA 3424692
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21418315515.507.80216002.00EPA 3549674
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21418315115.507.80216002.00EPA 3549675
5TXCD010AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21418313715.508.10218002.00EPA 3549677
5PX*C009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21568752515.508.00220002.10EPA 3651243

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →