Trane / AIR-SOURCE HEAT PUMP

5TWX5048A1

15 Single-Stage Heat Pump with WeatherGuard Top

101 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 101 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16101 / 101
EER2 · BTU/Wh11.7–12101 / 101
HSPF2 · BTU/Wh7.8–8.5101 / 101
Cooling capacity · BTU/h43,000–46,000101 / 101
Heating capacity at 47°F / 8.3°C · BTU/h42,000–44,000101 / 101
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,200101 / 101
Heating capacity at 5°F / −15°C · BTU/h21,400–22,600101 / 101
COP at 5°F / −15°C2–2.3101 / 101
Equipment / loop typeHP - Split System101 / 101
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)101 / 101
Compressor stagingSingle stage101 / 101
Connected capabilityNo101 / 101

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21568752316.008.10222002.10EPA 3651242 →
5PX*D008AS3+TSTAT+P0V0D000M50SDAHRI reference: 21568760116.008.00222002.10EPA 3651369 →
5PX*D010AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21568761216.008.00216002.10EPA 3651374 →
5PX*D010AS3+TSTAT+P0V0D000M50SDAHRI reference: 21568761516.008.10222002.20EPA 3651375 →
5PX*D010AS3+TSTAT+P0V0C000M50SDAHRI reference: 21568761416.008.10218002.10EPA 3651376 →
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21568766316.008.10222002.10EPA 3651391 →
5TXCD008AS3+TSTAT+P0V0D000M50SDAHRI reference: 21568770516.008.00222002.10EPA 3651487 →
5TEMCD06AV41+TDR+TSTATAHRI reference: 21586398416.008.10220002.30EPA 3737784 →
5TEMCD07AV51+TDR+TSTATAHRI reference: 21586398516.008.10220002.30EPA 3737785 →
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21418308815.508.10220002.10EPA 3423506 →
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PCAAHRI reference: 21418309015.507.80214002.10EPA 3423507 →
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PDAAHRI reference: 21418309415.507.80214002.10EPA 3423509 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCAAHRI reference: 21418309815.508.00220002.10EPA 3423511 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21418310015.507.80222002.10EPA 3423512 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDAAHRI reference: 21418310215.508.00220002.10EPA 3423513 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21418310415.507.80222002.10EPA 3423514 →
5TXCD010AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21418310815.507.80214002.10EPA 3423515 →
5TXCD010AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21418311215.507.80214002.10EPA 3423516 →
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21418311415.508.00222002.10EPA 3423517 →
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21418311615.508.00222002.10EPA 3423518 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →