Trane / AIR-SOURCE HEAT PUMP

5TWX5036A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 13

444 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 444 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5444 / 444
EER2 · BTU/Wh11.7–12444 / 444
HSPF2 · BTU/Wh7.8–8.5444 / 444
Cooling capacity · BTU/h31,800–35,000444 / 444
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,600444 / 444
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,200444 / 444
Heating capacity at 5°F / −15°C · BTU/h16,600–17,700444 / 444
COP at 5°F / −15°C2.1–2.4444 / 444
Equipment / loop typeHP - Split System444 / 444
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)444 / 444
Compressor stagingSingle stage444 / 444
Connected capabilityNo444 / 444

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B004AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21568680315.508.10173002.20EPA 3651556
5PX*B004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21568681015.508.10172002.30EPA 3651558
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21568683815.508.10174002.30EPA 3651576
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4PSCAHRI reference: 21568683915.508.10172002.30EPA 3651577
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21568684015.508.10172002.30EPA 3651578
5PX*B006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21568684115.508.10175002.20EPA 3651579
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21568684215.508.10173002.30EPA 3651580
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21568684315.508.10173002.30EPA 3651581
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21568684415.508.10175002.20EPA 3651582
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21568684515.508.10173002.30EPA 3651583
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21568684615.508.10173002.30EPA 3651584
5PX*B006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21568684915.508.10168002.20EPA 3651586
5PX*B006AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21568685115.508.10167002.20EPA 3651588
5PX*B006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21568685215.508.10167002.20EPA 3651589
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21568685315.508.10172002.30EPA 3651590
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21568685415.508.10172002.30EPA 3651591
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21568685515.508.10174002.30EPA 3651592
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21568685615.508.10174002.30EPA 3651593
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21568685715.508.10170002.20EPA 3651594
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21568685815.508.10170002.20EPA 3651595

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →