Trane / AIR-SOURCE HEAT PUMP

5TWX5036A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 14

444 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 444 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5444 / 444
EER2 · BTU/Wh11.7–12444 / 444
HSPF2 · BTU/Wh7.8–8.5444 / 444
Cooling capacity · BTU/h31,800–35,000444 / 444
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,600444 / 444
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,200444 / 444
Heating capacity at 5°F / −15°C · BTU/h16,600–17,700444 / 444
COP at 5°F / −15°C2.1–2.4444 / 444
Equipment / loop typeHP - Split System444 / 444
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)444 / 444
Compressor stagingSingle stage444 / 444
Connected capabilityNo444 / 444

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21568686115.508.10174002.30EPA 3651598
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21568686215.508.10174002.30EPA 3651599
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21568686315.508.10170002.20EPA 3651600
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21568686415.508.10170002.20EPA 3651601
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21568692715.508.10175002.20EPA 3651603
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21568692815.508.10175002.20EPA 3651604
5PX*BD06AS3+TSTAT+ furnace: *DHMB060CCV3AHRI reference: 21568693115.508.00174002.20EPA 3651607
5PX*BD06AS3+TSTAT+ furnace: *DHMB080CCV3AHRI reference: 21568693215.508.10175002.20EPA 3651608
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21568686615.508.10174002.30EPA 3651610
5PX*B006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21568686915.508.10168002.20EPA 3651613
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21568687015.508.10174002.30EPA 3651614
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21568687415.508.10174002.30EPA 3651616
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21568687315.508.10174002.30EPA 3651617
5PX*B006AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21568687515.508.10174002.30EPA 3651618
5PX*B006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21568687615.508.10174002.30EPA 3651619
5PX*B006AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21568687715.508.10174002.30EPA 3651620
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21568691215.508.10175002.20EPA 3651622
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3PSCAHRI reference: 21568691315.508.10175002.20EPA 3651623
5PX*BD06AS3+TSTAT+ furnace: S9V2B060D3PSCAHRI reference: 21568691415.508.10174002.20EPA 3651624
5PX*BD06AS3+TSTAT+ furnace: S9V2B060D3VSBAHRI reference: 21568691515.508.10174002.20EPA 3651625