Trane / AIR-SOURCE HEAT PUMP

5TWX5036A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 12

444 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 444 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5444 / 444
EER2 · BTU/Wh11.7–12444 / 444
HSPF2 · BTU/Wh7.8–8.5444 / 444
Cooling capacity · BTU/h31,800–35,000444 / 444
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,600444 / 444
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,200444 / 444
Heating capacity at 5°F / −15°C · BTU/h16,600–17,700444 / 444
COP at 5°F / −15°C2.1–2.4444 / 444
Equipment / loop typeHP - Split System444 / 444
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)444 / 444
Compressor stagingSingle stage444 / 444
Connected capabilityNo444 / 444

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21418256515.508.10172002.30EPA 3423910
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21418256815.508.10172002.30EPA 3423911
5TXCB006AS3+TSTAT+ furnace: *UHMB060ACV3AHRI reference: 21418257015.508.10172002.30EPA 3423912
5TXCB006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21418257215.508.10172002.30EPA 3423913
5TXCB006AS3+TSTAT+ furnace: *UHMB080ACV3AHRI reference: 21418257415.508.10171002.30EPA 3423914
5TXCB006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21418257615.508.10173002.30EPA 3424951
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21418258215.508.10173002.30EPA 3424954
5TXCB006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21418259015.508.00168002.20EPA 3424956
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21418261615.508.10170002.30EPA 3424964
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21418261815.508.10170002.30EPA 3424965
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21418262015.508.10172002.30EPA 3424966
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21418262215.508.10172002.30EPA 3424967
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21418262515.508.10170002.30EPA 3424968
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCAAHRI reference: 21418263915.508.10172002.30EPA 3424973
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDAAHRI reference: 21418264315.508.10172002.30EPA 3424974
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCAAHRI reference: 21418264715.508.10172002.30EPA 3424975
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDAAHRI reference: 21418265115.508.10172002.30EPA 3424977
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21418265715.508.10172002.30EPA 3424979
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21418265915.508.10169002.30EPA 3424980
5TEM6D05AV41+TDR+TSTATAHRI reference: 21561098215.508.50175002.30EPA 3651471

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →