Trane / AIR-SOURCE HEAT PUMP

5TWR6042A1

16 Single-Stage Heat Pump · source records, page 10

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810859615.207.80193002.18EPA 4574310
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810859415.207.80193002.18EPA 4574312
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810859215.207.80192002.18EPA 4574314
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810859015.207.80192002.18EPA 4574316
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810858815.207.80193002.18EPA 4574318
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21810858615.208.10193002.16EPA 4574320
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21810858415.208.10193002.16EPA 4574322
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810858215.207.80193002.18EPA 4574324
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810858015.207.80193002.18EPA 4574326
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21810857815.208.10193002.16EPA 4574328
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810857615.208.10193002.16EPA 4574330
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21810857415.207.80193002.18EPA 4574332
5TEM4D07AC51+TDR+TSTATAHRI reference: 21810854615.208.10188002.32EPA 4574346
5TEM4D06AC41+TDR+TSTATAHRI reference: 21810854415.208.10187002.31EPA 4574348
5TEM4D05AC41+TDR+TSTATAHRI reference: 21810854215.208.10190002.12EPA 4574350
5TAM5D05AC31+TSTATAHRI reference: 21810852615.208.00191002.12EPA 4574362
5PX*DD10AS3+TSTAT+ furnace: *DHMD120CCV5AHRI reference: 21810851815.208.10190002.22EPA 4574370
5PX*D008AS3+TSTAT+ furnace: S9V2D120D5VSBAHRI reference: 21810848615.208.10189002.21EPA 4574400
5PX*C007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810833415.208.10194002.17EPA 4574510
5PX*C007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21810833215.208.10194002.17EPA 4574512

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →