Trane / AIR-SOURCE HEAT PUMP

5TWR6042A1

16 Single-Stage Heat Pump · source records, page 9

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810865415.208.10194002.17EPA 4574264 →
5TXCC005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810864615.208.10193002.14EPA 4574272 →
5TXCC005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810864015.207.80193002.14EPA 4574274 →
5TXCC005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810863815.207.80193002.14EPA 4574276 →
5TXCC005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810863615.207.80193002.15EPA 4574278 →
5TXCC005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810863415.208.10193002.16EPA 4574280 →
5TXCC005AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21810863215.208.00193002.16EPA 4574282 →
5TXCC005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810862815.207.80193002.15EPA 4574284 →
5TXCC005AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810862615.207.80193002.15EPA 4574286 →
5TXCC005AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810862415.207.80193002.15EPA 4574288 →
5TXCC005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810862215.207.80193002.14EPA 4574290 →
5TXCC005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810862015.207.80193002.14EPA 4574292 →
5TXCC005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810861615.208.00190002.18EPA 4574294 →
5TXCC005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810861415.208.00192002.17EPA 4574296 →
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21810861215.208.10192002.19EPA 4574298 →
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21810861015.208.10192002.18EPA 4574300 →
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21810860815.208.10193002.19EPA 4574302 →
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21810860415.208.10193002.19EPA 4574304 →
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21810860015.207.80194002.16EPA 4574306 →
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810859815.208.10191002.21EPA 4574308 →