Trane / AIR-SOURCE HEAT PUMP

5TWR6042A1

16 Single-Stage Heat Pump · source records, page 11

248 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,600–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 248 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5248 / 248
EER2 · BTU/Wh11.7–12248 / 248
HSPF2 · BTU/Wh7.8–8.5248 / 248
Cooling capacity · BTU/h37,600–41,500248 / 248
Heating capacity at 47°F / 8.3°C · BTU/h37,600–40,500248 / 248
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,200248 / 248
Heating capacity at 5°F / −15°C · BTU/h18,700–19,900248 / 248
COP at 5°F / −15°C2.12–2.32248 / 248
Equipment / loop typeHP - Split System248 / 248
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)248 / 248
Compressor stagingSingle stage248 / 248
Connected capabilityNo248 / 248

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810831415.207.80193002.15EPA 4574528
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810831215.208.00193002.14EPA 4574530
5PX*C005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810830815.208.00192002.17EPA 4574532
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810830415.208.10193002.15EPA 4574534
5PX*C005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810830215.208.10193002.16EPA 4574536
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810830015.207.80193002.15EPA 4574538
5PX*C005AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21810829615.208.00193002.16EPA 4574540
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810829415.207.80193002.15EPA 4574542
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810829215.208.00193002.14EPA 4574544
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810829015.208.00193002.14EPA 4574546
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810828815.208.00193002.14EPA 4574548
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810828615.208.10190002.17EPA 4574550
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810825215.208.00192002.19EPA 4574552
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810825015.208.00193002.18EPA 4574554
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21810824615.208.00194002.16EPA 4574558
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21810824415.208.10192002.20EPA 4574560
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21810824215.208.10192002.20EPA 4574562
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21810824015.208.10192002.18EPA 4574564
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21810823815.208.10194002.18EPA 4574566
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810823615.208.00193002.19EPA 4574568