Trane / AIR-SOURCE HEAT PUMP

5TWR5048A1

15 Single-Stage Heat Pump · source records, page 5

167 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–45,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 167 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16167 / 167
EER2 · BTU/Wh11.7–12167 / 167
HSPF2 · BTU/Wh7.8–8.5167 / 167
Cooling capacity · BTU/h43,000–45,500167 / 167
Heating capacity at 47°F / 8.3°C · BTU/h41,500–44,000167 / 167
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,400167 / 167
Heating capacity at 5°F / −15°C · BTU/h21,200–22,600167 / 167
COP at 5°F / −15°C2–2.3167 / 167
Equipment / loop typeHP - Split System167 / 167
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)167 / 167
Compressor stagingSingle stage167 / 167
Connected capabilityNo167 / 167

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21407902115.208.10224002.00EPA 3423584
5TXCC007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21407902315.208.10224002.00EPA 3423586
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21407902515.208.10226002.00EPA 3423588
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSBAHRI reference: 21407902715.208.10226002.00EPA 3423590
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21407902915.207.80222002.10EPA 3423592
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21407903115.207.80222002.10EPA 3423594
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDAAHRI reference: 21407903315.207.80224002.10EPA 3423596
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCAAHRI reference: 21407903515.207.80224002.10EPA 3423598
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21407903715.208.10226002.00EPA 3423600
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDAAHRI reference: 21407903915.207.80224002.00EPA 3423602
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCAAHRI reference: 21407904115.207.80224002.00EPA 3423604
5TXCD010AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21407904315.207.80214002.10EPA 3423606
5TXCD010AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21407904515.207.80214002.10EPA 3423608
5TXCD010AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21407904715.207.80214002.10EPA 3423610
5TXCD010AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21407905315.207.80214002.10EPA 3423616
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PCAAHRI reference: 21407910715.207.80216002.10EPA 3424516
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21407910915.207.80216002.10EPA 3424518
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PDAAHRI reference: 21407911115.207.80216002.10EPA 3424520
5TXCD010AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21407911315.207.80216002.10EPA 3424522
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PCAAHRI reference: 21407911515.207.80214002.10EPA 3424524

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →