Trane / AIR-SOURCE HEAT PUMP

5TWR5048A1

15 Single-Stage Heat Pump · source records, page 4

167 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–45,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 167 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16167 / 167
EER2 · BTU/Wh11.7–12167 / 167
HSPF2 · BTU/Wh7.8–8.5167 / 167
Cooling capacity · BTU/h43,000–45,500167 / 167
Heating capacity at 47°F / 8.3°C · BTU/h41,500–44,000167 / 167
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,400167 / 167
Heating capacity at 5°F / −15°C · BTU/h21,200–22,600167 / 167
COP at 5°F / −15°C2–2.3167 / 167
Equipment / loop typeHP - Split System167 / 167
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)167 / 167
Compressor stagingSingle stage167 / 167
Connected capabilityNo167 / 167

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 21407898115.207.80226002.00EPA 3423544 →
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCAAHRI reference: 21407898315.207.80226002.00EPA 3423547 →
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDAAHRI reference: 21407898515.207.80224002.00EPA 3423548 →
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCAAHRI reference: 21407898715.207.80224002.00EPA 3423550 →
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407898915.207.80224002.00EPA 3423552 →
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21407899115.207.80224002.00EPA 3423554 →
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21407899315.207.80226002.00EPA 3423556 →
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSBAHRI reference: 21407899515.207.80224002.00EPA 3423558 →
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSBAHRI reference: 21407899715.207.80226002.00EPA 3423560 →
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21407899915.208.10226002.00EPA 3423562 →
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21407900115.207.80224002.10EPA 3423564 →
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21407900315.207.80224002.10EPA 3423566 →
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21407900515.207.80222002.10EPA 3423568 →
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21407900715.207.80222002.10EPA 3423570 →
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21407900915.207.80224002.10EPA 3423572 →
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21407901115.207.80224002.10EPA 3423574 →
5TXCC007AS3+TSTAT+P0V0C000M50SDAHRI reference: 21407901315.207.80222002.10EPA 3423576 →
5TXCC007AS3+TSTAT+P0V0C000M50SCAHRI reference: 21407901515.207.80222002.10EPA 3423578 →
5TXCC007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21407901715.207.80222002.10EPA 3423580 →
5TXCC007AS3+TSTAT+ furnace: *UHMC100ACV4AHRI reference: 21407901915.207.80222002.10EPA 3423582 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.