Trane / AIR-SOURCE HEAT PUMP

5TWR5048A1

15 Single-Stage Heat Pump · source records, page 6

167 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–45,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 167 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16167 / 167
EER2 · BTU/Wh11.7–12167 / 167
HSPF2 · BTU/Wh7.8–8.5167 / 167
Cooling capacity · BTU/h43,000–45,500167 / 167
Heating capacity at 47°F / 8.3°C · BTU/h41,500–44,000167 / 167
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,400167 / 167
Heating capacity at 5°F / −15°C · BTU/h21,200–22,600167 / 167
COP at 5°F / −15°C2–2.3167 / 167
Equipment / loop typeHP - Split System167 / 167
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)167 / 167
Compressor stagingSingle stage167 / 167
Connected capabilityNo167 / 167

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21407911715.207.80214002.10EPA 3424526
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PDAAHRI reference: 21407911915.207.80214002.10EPA 3424528
5TXCD010AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21407912115.207.80214002.10EPA 3424530
5TXCD010AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21407913115.207.80214002.10EPA 3424540
5TXCD010AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21407905515.207.80214002.10EPA 3424794
5TXCD010AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21407905715.207.80214002.10EPA 3424797
5TXCD010AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21407905915.207.80214002.10EPA 3424800
5TXCD010AS3+TSTAT+ furnace: S9V2C080U5PSBAHRI reference: 21407906515.208.10216002.10EPA 3424805
5TXCD010AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21407906715.208.10216002.10EPA 3424807
5TXCD010AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21407906915.208.10218002.10EPA 3424809
5TXCD010AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21407907115.208.10218002.10EPA 3424811
5TXCD010AS3+TSTAT+ furnace: S9V2C100U5PSBAHRI reference: 21407907315.208.10214002.10EPA 3424813
5TXCD010AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21407907515.208.10214002.10EPA 3424815
5TXCD010AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21407908515.208.10216002.10EPA 3424825
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21407908715.208.10220002.20EPA 3424827
5TXCD010AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21407908915.208.10216002.10EPA 3424829
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21407909115.208.10220002.20EPA 3424831
5TXCD010AS3+TSTAT+ furnace: *UHMC100ACV4AHRI reference: 21407909315.208.10220002.00EPA 3424833
5TXCD010AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21407909515.208.10220002.00EPA 3424835
5TXCD010AS3+TSTAT+ furnace: *UHMD120ACV5AHRI reference: 21407909715.208.10220002.20EPA 3424837

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →