Trane / AIR-SOURCE HEAT PUMP

5TWR5048A1

15 Single-Stage Heat Pump · source records, page 3

167 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–45,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 167 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16167 / 167
EER2 · BTU/Wh11.7–12167 / 167
HSPF2 · BTU/Wh7.8–8.5167 / 167
Cooling capacity · BTU/h43,000–45,500167 / 167
Heating capacity at 47°F / 8.3°C · BTU/h41,500–44,000167 / 167
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,400167 / 167
Heating capacity at 5°F / −15°C · BTU/h21,200–22,600167 / 167
COP at 5°F / −15°C2–2.3167 / 167
Equipment / loop typeHP - Split System167 / 167
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)167 / 167
Compressor stagingSingle stage167 / 167
Connected capabilityNo167 / 167

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D010AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556944016.008.10214002.10EPA 3651023 →
5PX*D010AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556944616.008.00216002.10EPA 3651026 →
5PX*D010AS3+TSTAT+ furnace: S9V2D120U5PSCAHRI reference: 21556945216.008.10222002.10EPA 3651031 →
5PX*D010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21556945416.008.10224002.10EPA 3651033 →
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21556946416.008.10222002.20EPA 3651039 →
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21556946616.008.10222002.20EPA 3651041 →
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21556947616.008.10222002.20EPA 3651047 →
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556663816.008.10222002.20EPA 3651050 →
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556664216.008.00220002.20EPA 3651052 →
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21556947816.008.10222002.20EPA 3651091 →
5PX*D010AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556948016.008.00218002.10EPA 3651093 →
5PX*D010AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556948216.008.00218002.10EPA 3651095 →
5PX*DD10AS3+TSTAT+P0V0D000M50SDAHRI reference: 21556950616.008.10220002.10EPA 3651105 →
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583155016.008.10222002.10EPA 3737729 →
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583155216.008.10222002.10EPA 3737731 →
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583157616.008.10222002.10EPA 3737737 →
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583157816.008.10222002.10EPA 3737739 →
5TEMCD06AV41+TDR+TSTATAHRI reference: 21586395216.008.10216002.30EPA 3737757 →
5TEMCD07AV51+TDR+TSTATAHRI reference: 21586395416.008.50222002.30EPA 3737759 →
5TAM5D06AC41+TSTATAHRI reference: 21602196116.008.10222002.10EPA 3845935 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →