Trane / AIR-SOURCE HEAT PUMP

5TWR5048A1

15 Single-Stage Heat Pump · source records, page 2

167 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–45,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 167 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16167 / 167
EER2 · BTU/Wh11.7–12167 / 167
HSPF2 · BTU/Wh7.8–8.5167 / 167
Cooling capacity · BTU/h43,000–45,500167 / 167
Heating capacity at 47°F / 8.3°C · BTU/h41,500–44,000167 / 167
Heating capacity at 17°F / −8.3°C · BTU/h27,600–29,400167 / 167
Heating capacity at 5°F / −15°C · BTU/h21,200–22,600167 / 167
COP at 5°F / −15°C2–2.3167 / 167
Equipment / loop typeHP - Split System167 / 167
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)167 / 167
Compressor stagingSingle stage167 / 167
Connected capabilityNo167 / 167

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556924416.008.00220002.20EPA 3650635
5PX*C009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556924616.008.10222002.20EPA 3650637
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556926816.008.00222002.10EPA 3650650
5PX*C009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556927016.008.10226002.10EPA 3650653
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556927416.008.10224002.10EPA 3650658
5PX*D008AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556939016.008.00220002.00EPA 3650823
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556661216.008.10226002.10EPA 3650862
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556661416.008.10224002.10EPA 3650864
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556662016.008.00222002.10EPA 3650870
5PX*D008AS3+TSTAT+P0V0D000M50SDAHRI reference: 21556941216.008.10224002.10EPA 3650997
5PX*D010AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556941616.008.10218002.10EPA 3650999
5PX*D010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21556941816.008.10224002.10EPA 3651001
5PX*D010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21556942016.008.10222002.20EPA 3651003
5PX*D010AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556942216.008.10218002.10EPA 3651005
5PX*D010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21556942616.008.10222002.20EPA 3651009
5PX*D010AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556943016.008.00218002.10EPA 3651013
5PX*D010AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556943216.008.00218002.10EPA 3651015
5PX*D010AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21556943416.008.00216002.10EPA 3651017
5PX*D010AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21556943616.008.00216002.10EPA 3651019
5PX*D010AS3+TSTAT+P0V0D000M50SDAHRI reference: 21556943816.008.10220002.20EPA 3651021