Trane / AIR-SOURCE HEAT PUMP

5TWR5030A1

15 Single-Stage Heat Pump · source records, page 6

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16140 / 140
EER2 · BTU/Wh11.7–12140 / 140
HSPF2 · BTU/Wh7.8–8.1140 / 140
Cooling capacity · BTU/h26,400–29,200140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700140 / 140
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800140 / 140
COP at 5°F / −15°C2–2.2140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingSingle stage140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PDAAHRI reference: 21407846115.207.80129002.00EPA 3424631
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21407846315.207.80129002.00EPA 3424633
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCAAHRI reference: 21407846515.207.80133002.10EPA 3424635
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21407846715.207.80133002.10EPA 3424637
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDAAHRI reference: 21407846915.207.80133002.10EPA 3424639
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21407847115.207.80133002.10EPA 3424641
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCAAHRI reference: 21407847315.207.80133002.10EPA 3424643
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21407847515.207.80133002.10EPA 3424646
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 21407847715.207.80133002.10EPA 3424647
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21407847915.208.10134002.10EPA 3424649
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21407848115.208.10135002.10EPA 3424651
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21407848315.208.10134002.10EPA 3424653
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSBAHRI reference: 21407848515.208.10134002.10EPA 3424655
5TXCC007AS3+TSTAT+ furnace: *UHMC100ACV4AHRI reference: 21407848715.207.80129002.10EPA 3424657
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCAAHRI reference: 21407848915.207.80132002.10EPA 3424659
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21407849115.207.80131002.10EPA 3424661
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDAAHRI reference: 21407849315.207.80132002.10EPA 3424663
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3PSBAHRI reference: 21407841515.208.10138002.10EPA 3424771
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21407841715.208.10138002.10EPA 3424773
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSAAHRI reference: 21407841915.208.10138002.10EPA 3424775

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.