Trane / AIR-SOURCE HEAT PUMP

5TWR5030A1

15 Single-Stage Heat Pump · source records, page 5

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16140 / 140
EER2 · BTU/Wh11.7–12140 / 140
HSPF2 · BTU/Wh7.8–8.1140 / 140
Cooling capacity · BTU/h26,400–29,200140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700140 / 140
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800140 / 140
COP at 5°F / −15°C2–2.2140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingSingle stage140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: *UHMD120ACV5AHRI reference: 21407851915.208.10130002.20EPA 3424434
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSBAHRI reference: 21407842315.208.10137002.10EPA 3424593
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21407842515.208.10137002.10EPA 3424595
5TXCB006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21407842715.207.80130002.00EPA 3424597
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21407842915.207.80130002.00EPA 3424599
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21407843115.207.80133002.10EPA 3424601
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSBAHRI reference: 21407843315.208.10132002.10EPA 3424603
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSCAHRI reference: 21407843515.208.10136002.10EPA 3424605
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 21407843715.208.10138002.10EPA 3424607
5TXCB006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21407843915.208.10135002.10EPA 3424609
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21407844115.208.10136002.10EPA 3424611
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21407844315.208.10136002.10EPA 3424613
5TXCB006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21407844515.208.10135002.10EPA 3424615
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21407844715.208.10136002.10EPA 3424617
5TXCB006AS3+TSTAT+ furnace: *UHMB060ACV3AHRI reference: 21407845115.208.10133002.10EPA 3424619
5TXCB006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21407845315.208.10133002.10EPA 3424621
5TXCB006AS3+TSTAT+ furnace: *UHMB080ACV3AHRI reference: 21407845515.208.10131002.10EPA 3424624
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407844915.208.10136002.10EPA 3424625
5TXCB006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21407845715.207.80131002.10EPA 3424627
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21407845915.207.80129002.00EPA 3424629

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →