Trane / AIR-SOURCE HEAT PUMP

5TWR5030A1

15 Single-Stage Heat Pump · source records, page 7

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16140 / 140
EER2 · BTU/Wh11.7–12140 / 140
HSPF2 · BTU/Wh7.8–8.1140 / 140
Cooling capacity · BTU/h26,400–29,200140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700140 / 140
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800140 / 140
COP at 5°F / −15°C2–2.2140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingSingle stage140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21407842115.208.10138002.10EPA 3424778 →
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556800415.208.00135002.10EPA 3650117 →
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556800615.208.00135002.10EPA 3650119 →
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556801215.208.00135002.10EPA 3650125 →
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556801415.208.00135002.10EPA 3650127 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556801615.208.10137002.00EPA 3650129 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556801815.208.10138002.00EPA 3650131 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21556802015.208.00136002.10EPA 3650133 →
5PX*CD07AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21556802215.208.00136002.10EPA 3650135 →
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556795615.208.10134002.10EPA 3650147 →
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556795815.208.10134002.10EPA 3650149 →
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556796015.208.10134002.10EPA 3650151 →
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556796215.208.10134002.10EPA 3650153 →
5TEM4B03AC31+TDR+TSTATAHRI reference: 21561092115.207.80134002.20EPA 3651408 →
5TEM4D04AC31+TDR+TSTATAHRI reference: 21561092315.208.10134002.10EPA 3651410 →
5TEM4D05AC41+TDR+TSTATAHRI reference: 21561092515.208.10133002.10EPA 3651412 →
5TEM4D06AC41+TDR+TSTATAHRI reference: 21561092715.208.10134002.20EPA 3651414 →
5TEMCB02AV21+TDR+TSTATAHRI reference: 21586392415.207.80134002.20EPA 3737596 →
5TEMCB03AV31+TDR+TSTATAHRI reference: 21586392615.208.10135002.10EPA 3737598 →
5TEM4B04AC31+TDR+TSTATAHRI reference: 21815461315.208.00137002.00EPA 4575870 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →