Johnson Controls / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 2

192 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2192 / 192
EER2 · BTU/Wh11–12192 / 192
HSPF2 · BTU/Wh7.8–8.1192 / 192
Cooling capacity · BTU/h44,500–48,000192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200192 / 192
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000192 / 192
COP at 5°F / −15°C2.1–2.42192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)192 / 192
Compressor stagingTwo-stage192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21574307915.207.80260002.40EPA 3653180
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21574310515.207.80262002.38EPA 3653187
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21574311015.207.80260002.40EPA 3653189
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21643782515.208.00260002.40EPA 3815059
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21643783015.207.80262002.34EPA 3815064
CTM60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21643783515.208.00260002.40EPA 3815069
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21643784015.208.10262002.40EPA 3815074
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21643784515.208.00260002.40EPA 3815079
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21643785015.208.00258002.38EPA 3815084
CTM60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21643785515.208.00264002.36EPA 3815089
CTM60D5CHS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21643786015.208.00266002.36EPA 3815094
CTM60C5CHS1+JME12C2SN1AHRI reference: 21443200215.208.10258002.42EPA 3892771
CTM60C5CHS1+JMVT16CC2N1AHRI reference: 21443199815.208.10262002.42EPA 3892772
CTM60D5CHS1+JME18D2SN1AHRI reference: 21442607615.208.10262002.42EPA 3892779
CTM60C5CHS1+JMET16CS2N1AHRI reference: 21442663215.208.10264002.40EPA 3892784
CTM60D5CHS1+JMET18DS2N1AHRI reference: 21442664215.208.10262002.42EPA 3892785
JHC48C5CG2SS1AHRI reference: 21442670015.207.80248002.26EPA 3892790
CTM60C5CGS1+JME12C2SN1AHRI reference: 21442734215.207.80252002.30EPA 3892795
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460536315.208.10264002.38EPA 3892821
CTM60C5CHS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21460522315.207.80260002.36EPA 3892827

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →