Johnson Controls / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES

192 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2192 / 192
EER2 · BTU/Wh11–12192 / 192
HSPF2 · BTU/Wh7.8–8.1192 / 192
Cooling capacity · BTU/h44,500–48,000192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200192 / 192
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000192 / 192
COP at 5°F / −15°C2.1–2.42192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)192 / 192
Compressor stagingTwo-stage192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+ furnace: TM8E120C20MP11AHRI reference: 21442696515.207.80260002.36EPA 3558371
JHE48D5CG2SS1AHRI reference: 21442735715.207.80246002.26EPA 3558481
JHE60C5CH2SS1AHRI reference: 21442740315.208.10264002.40EPA 3558561
CTF60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 21442805215.207.80258002.36EPA 3558894
CTF60C5CHS1+ furnace: TM8Y100C20MP11AHRI reference: 21442805715.207.80258002.36EPA 3558899
CTM60C5CHS1+ furnace: TM8E100C20MP11AHRI reference: 21442806215.207.80260002.36EPA 3558931
CTM60C5CHS1+ furnace: TM8E120C20MP11AHRI reference: 21442807215.207.80260002.36EPA 3558941
JHC60D5CH2SS1AHRI reference: 21442829315.208.10264002.42EPA 3558962
JHE60D5CH2SS1AHRI reference: 21442829815.208.10262002.42EPA 3559022
CTM60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 21442844315.207.80262002.36EPA 3559027
CTM60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 21442844815.207.80262002.36EPA 3559032
CTM60C5CHS1+ furnace: TM8Y080C16MP11AHRI reference: 21442847015.207.80258002.36EPA 3559042
CTF60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 21442868315.207.80258002.36EPA 3559047
JHC48D5CG2SS1AHRI reference: 21442876415.207.80248002.26EPA 3559077
CTF60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 21442901315.207.80262002.36EPA 3559087
CTF60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 21442901815.207.80262002.36EPA 3559092
JHC60C5CH2SS1AHRI reference: 21442931315.208.10266002.38EPA 3559106
JSC48D5CG2SS1AHRI reference: 21483353515.207.80248002.26EPA 3560534
JSE48D5CG2SS1AHRI reference: 21483354015.207.80246002.26EPA 3560539
JHE48C5CG2SS1AHRI reference: 21442473515.207.80248002.10EPA 3627825

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →