XH548E2S11
LX SERIES · source records, page 3
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 192 / 192 |
| EER2 · BTU/Wh | 11–12 | 192 / 192 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 192 / 192 |
| Cooling capacity · BTU/h | 44,500–48,000 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,200 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,000 | 192 / 192 |
| COP at 5°F / −15°C | 2.1–2.42 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Two-stage | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: Z9ES100C16SMPS1AHRI reference: 214605228 | 15.20 | 7.80 | 26600 | 2.34 | EPA 3892835 → |
CTM60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 214605263 | 15.20 | 7.80 | 26600 | 2.36 | EPA 3892839 → |
CTM60C5CHS1+ furnace: Z8ES100C16SMPS1AHRI reference: 214605288 | 15.20 | 8.10 | 26600 | 2.36 | EPA 3892842 → |
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 214605293 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3892849 → |
CTM60D5CGS1+JMC20D2SN1AHRI reference: 214428614 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892856 → |
CTM60C5CHS1+JME16C2SN1AHRI reference: 214428619 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892859 → |
CTM60D5CHS1+JMC20D2SN1AHRI reference: 214428877 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892865 → |
CTM60C5CGS1+JME16C2SN1AHRI reference: 214429003 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892870 → |
CTM60C5CHS1+JMVT17CC2N1AHRI reference: 214429318 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892873 → |
CTM60C5CHS1+JMC17C2SN1AHRI reference: 214429323 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892882 → |
CTM60D5CGS1+JMVT20DC2N1AHRI reference: 214429363 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892884 → |
CTM60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 214605483 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3892913 → |
CTM60D5CGS1+JME18D2SN1AHRI reference: 214427443 | 15.20 | 7.80 | 25400 | 2.30 | EPA 3892916 → |
CTM60C5CHS1+JMC16C2SN1AHRI reference: 214427794 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892925 → |
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 214427799 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892929 → |
CTM60C5CGS1+JMVT17CC2N1AHRI reference: 214428205 | 15.20 | 7.80 | 25600 | 2.28 | EPA 3892934 → |
CTM60C5CHS1+JMET12CS2N1AHRI reference: 214432025 | 15.20 | 7.80 | 25800 | 2.40 | EPA 3892939 → |
CTM60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 214605478 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892942 → |
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 214605698 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892950 → |
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 214605838 | 15.20 | 8.10 | 26200 | 2.38 | EPA 3892952 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →