Johnson Controls / AIR-SOURCE HEAT PUMP

HL19B2421

MOMENTUM

85 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity21,200–24,200BTU/h

Each efficiency range summarizes published EPA records for HL19B2421. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1885 / 85
EER2 · BTU/Wh11.7–1485 / 85
HSPF2 · BTU/Wh7.885 / 85
Cooling capacity · BTU/h21,200–24,20085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h22,400–23,80085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,20085 / 85
Heating capacity at 5°F / −15°C · BTU/h10,900–12,20085 / 85
COP at 5°F / −15°C1.8–2.0685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-410A (GWP:2088)85 / 85
Compressor stagingTwo-stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHVTB36DBAC2N1AHRI reference: 21127507618.007.80109002.02EPA 2481502
JHETB30DBAS2N1AHRI reference: 21127514118.007.80109002.02EPA 2481503
XAFB36DXXN1+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 21176905818.007.80109001.80EPA 3990232
XAFB36DBAN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21176906018.007.80109001.80EPA 3990234
XAFB36DXXN1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21248659218.007.80110001.80EPA 3990932
XAFB36DXXN1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21248659718.007.80110001.80EPA 3990939
XAFB36DBAN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21248660218.007.80110001.80EPA 3990941
XAFB36DBAN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21248661218.007.80110001.80EPA 3990944
XAFB36DXXN1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21085103117.007.80109001.96EPA 2477245
XAFA30DBAN1+ furnace: TM8Y060A12MP11AHRI reference: 21085102617.007.80113001.94EPA 2479931
XAFA30DBAN1+ furnace: TM9E060A10MP12AHRI reference: 21084514617.007.80113001.92EPA 2481398
XAFB36DXXN1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21084514817.007.80109001.96EPA 2481399
XAFB36DBAN1+ furnace: TM9E060B12MP12AHRI reference: 21084515617.007.80112001.96EPA 2481401
XAFB36DXXN1+TXV+ furnace: TM9E080B12MP12AHRI reference: 21084515917.007.80111001.98EPA 2481406
XAFB36DXXN1+TXV+ furnace: TM8V080B12MP12AHRI reference: 21084516017.007.80111001.96EPA 2481408
XAFB36DXXN1+TXV+ furnace: TM9Y060B12MP11AHRI reference: 21084647017.007.80110001.96EPA 2481414
XAFB36DXXN1+TXV+ furnace: TM9V060B12MP12AHRI reference: 21084647317.007.80111001.96EPA 2481417
XAFB36DBAN1+ furnace: TM9Y080B12MP11AHRI reference: 21084648417.007.80110001.96EPA 2481419
XAFB36DXXN1+TXV+ furnace: TM9E060B12MP12AHRI reference: 21084648517.007.80112001.96EPA 2481420
XAFB36DBAN1+ furnace: TL9E060B12UH11AHRI reference: 21084648717.007.80111001.94EPA 2481422

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.