XH518E2S11
LX SERIES · source records, page 2
138 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 138 / 138 |
| EER2 · BTU/Wh | 12–12.5 | 138 / 138 |
| HSPF2 · BTU/Wh | 7.8 | 138 / 138 |
| Cooling capacity · BTU/h | 17,000–18,300 | 138 / 138 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 138 / 138 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 138 / 138 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 138 / 138 |
| COP at 5°F / −15°C | 2.26–2.34 | 138 / 138 |
| Equipment / loop type | HP - Split System | 138 / 138 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 138 / 138 |
| Compressor staging | Single stage | 138 / 138 |
| Connected capability | No | 138 / 138 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF24B5ABS1+JMC12B2SN1AHRI reference: 215740394 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652751 → |
CTF30B5ACS1+JMET08BS2N1AHRI reference: 215740399 | 15.20 | 7.80 | 9000 | 2.34 | EPA 3652756 → |
CTM30B5ACS1+JMC12B2SN1AHRI reference: 215740406 | 15.20 | 7.80 | 9000 | 2.32 | EPA 3652762 → |
CTM30B5ACS1+JME12B2SN1AHRI reference: 215740411 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652767 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 215740416 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652773 → |
CTU30B5XCS1+JMET08BS2N1+TXVAHRI reference: 215740421 | 15.20 | 7.80 | 9000 | 2.34 | EPA 3652780 → |
CTF24A5ABS1+ furnace: TM8V060A12MP12AHRI reference: 215820536 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712595 → |
CTF24A5ABS1+ furnace: TMLV060A12MP12AHRI reference: 215820541 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712600 → |
CTF24A5ABS1+ furnace: TPLC060A12MP13AHRI reference: 215820546 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712605 → |
CTU24A5XBS1+TXV+ furnace: TM8V060A12MP12AHRI reference: 215820553 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712612 → |
CTU24A5XBS1+TXV+ furnace: TMLV060A12MP12AHRI reference: 215820558 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712617 → |
CTU24A5XBS1+TXV+ furnace: TPLC060A12MP13AHRI reference: 215820563 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712622 → |
CTF24B5ABS1+ furnace: Z9ET080B12SMPS1AHRI reference: 215820585 | 15.20 | 7.80 | 9000 | 2.28 | EPA 3712628 → |
CTU30B5XCS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 215820960 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3712669 → |
CTF30B5ACS1+ furnace: Z8ES100B12SMPS1AHRI reference: 215820955 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3712671 → |
CTM30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 215820471 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3712680 → |
CTF30B5ACS1+ furnace: TL9E060B12UH11AHRI reference: 215820476 | 15.20 | 7.80 | 9100 | 2.26 | EPA 3712685 → |
CTU30B5XCS1+TXV+ furnace: TL9E060B12UH11AHRI reference: 215820481 | 15.20 | 7.80 | 9100 | 2.26 | EPA 3712689 → |
CTM30B5ACS1+ furnace: TM8E100B12MP11AHRI reference: 215820491 | 15.20 | 7.80 | 9100 | 2.28 | EPA 3712695 → |
CTM30B5ACS1+ furnace: TMLE100B12MP11AHRI reference: 215820496 | 15.20 | 7.80 | 9100 | 2.28 | EPA 3712700 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →