XH518E2S11
LX SERIES · source records, page 3
138 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 138 / 138 |
| EER2 · BTU/Wh | 12–12.5 | 138 / 138 |
| HSPF2 · BTU/Wh | 7.8 | 138 / 138 |
| Cooling capacity · BTU/h | 17,000–18,300 | 138 / 138 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 138 / 138 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 138 / 138 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 138 / 138 |
| COP at 5°F / −15°C | 2.26–2.34 | 138 / 138 |
| Equipment / loop type | HP - Split System | 138 / 138 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 138 / 138 |
| Compressor staging | Single stage | 138 / 138 |
| Connected capability | No | 138 / 138 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 215820501 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3712703 → |
CTU30B5XCS1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 215820506 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3712710 → |
CTM24A5ABS1+ furnace: Z8ET060A12LMPS1AHRI reference: 215820980 | 15.20 | 7.80 | 8800 | 2.26 | EPA 3712714 → |
CTF24A5ABS1+ furnace: Z8ES040A12SMPS1AHRI reference: 215820990 | 15.20 | 7.80 | 8800 | 2.28 | EPA 3712721 → |
CTU24A5XBS1+TXV+ furnace: Z8ES040A12SMPS1AHRI reference: 215820995 | 15.20 | 7.80 | 8800 | 2.28 | EPA 3712725 → |
CTF24B5ABS1+ furnace: TMLE080B12MP11AHRI reference: 215820451 | 15.20 | 7.80 | 9100 | 2.26 | EPA 3712730 → |
CTM24A5ABS1+ furnace: Z8ES060A12SMPS1AHRI reference: 215820526 | 15.20 | 7.80 | 9000 | 2.28 | EPA 3712735 → |
CTF30B5ACS1+ furnace: TM8E080B12MP11AHRI reference: 215820187 | 15.20 | 7.80 | 8800 | 2.28 | EPA 3712754 → |
CTM24B5ABS1+ furnace: TMLE100B12MP11AHRI reference: 215820607 | 15.20 | 7.80 | 9100 | 2.26 | EPA 3712764 → |
CTM24B5ABS1+ furnace: TM8E100B12MP11AHRI reference: 215820602 | 15.20 | 7.80 | 9100 | 2.26 | EPA 3712765 → |
CTF24B5ABS1+ furnace: TM8E100B12MP11AHRI reference: 215820612 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712772 → |
CTF24B5ABS1+ furnace: TMLE100B12MP11AHRI reference: 215820617 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712777 → |
CTM30B5ACS1+ furnace: Z8ET080B12LMPS1AHRI reference: 215820632 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3712782 → |
CTM30B5ACS1+ furnace: TM9Y060B12MP11AHRI reference: 215820627 | 15.20 | 7.80 | 8800 | 2.28 | EPA 3712783 → |
CTF30B5ACS1+ furnace: TM8E100B12MP11AHRI reference: 215820637 | 15.20 | 7.80 | 8900 | 2.28 | EPA 3712794 → |
CTF30B5ACS1+ furnace: TMLE100B12MP11AHRI reference: 215820642 | 15.20 | 7.80 | 8900 | 2.28 | EPA 3712797 → |
CTU30B5XCS1+TXV+ furnace: TMLE100B12MP11AHRI reference: 215820652 | 15.20 | 7.80 | 8900 | 2.28 | EPA 3712801 → |
CTU30B5XCS1+TXV+ furnace: TM8E100B12MP11AHRI reference: 215820647 | 15.20 | 7.80 | 8900 | 2.28 | EPA 3712805 → |
CTF30B5ACS1+ furnace: TM9V080B12MP12AHRI reference: 215820657 | 15.20 | 7.80 | 9000 | 2.30 | EPA 3712810 → |
CTF30B5ACS1+ furnace: TP9C080B12MP13AHRI reference: 215820662 | 15.20 | 7.80 | 9000 | 2.30 | EPA 3712813 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →