XH518E2S11
LX SERIES
138 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 138 / 138 |
| EER2 · BTU/Wh | 12–12.5 | 138 / 138 |
| HSPF2 · BTU/Wh | 7.8 | 138 / 138 |
| Cooling capacity · BTU/h | 17,000–18,300 | 138 / 138 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 138 / 138 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 138 / 138 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 138 / 138 |
| COP at 5°F / −15°C | 2.26–2.34 | 138 / 138 |
| Equipment / loop type | HP - Split System | 138 / 138 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 138 / 138 |
| Compressor staging | Single stage | 138 / 138 |
| Connected capability | No | 138 / 138 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHE24B5AC2SS1AHRI reference: 215740147 | 15.20 | 7.80 | 8900 | 2.28 | EPA 3652653 → |
CTM24B5ABS1+JME12B2SN1AHRI reference: 215740303 | 15.20 | 7.80 | 8800 | 2.32 | EPA 3652660 → |
CTF24B5ABS1+JME08B2SN1AHRI reference: 215740308 | 15.20 | 7.80 | 8800 | 2.32 | EPA 3652665 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 215740313 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652670 → |
CTF30B5ACS1+JME08B2SN1AHRI reference: 215740318 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652675 → |
CTM30B5ACS1+JMET08BS2N1AHRI reference: 215740325 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652682 → |
CTM24B5ABS1+JMET12BS2N1AHRI reference: 215740330 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652687 → |
CTM30B5ACS1+JMET12BS2N1AHRI reference: 215740335 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652692 → |
CTU30B5XCS1+JME08B2SN1+TXVAHRI reference: 215740340 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652697 → |
CTF30B5ACS1+JMET12BS2N1AHRI reference: 215740346 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652703 → |
CTM30B5ACS1+JME08B2SN1AHRI reference: 215740351 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652708 → |
CTM24B5ABS1+JMET08BS2N1AHRI reference: 215740356 | 15.20 | 7.80 | 8900 | 2.30 | EPA 3652713 → |
CTF24B5ABS1+JME12B2SN1AHRI reference: 215740361 | 15.20 | 7.80 | 8800 | 2.32 | EPA 3652718 → |
CTF30B5ACS1+JMC12B2SN1AHRI reference: 215740362 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652719 → |
CTU30B5XCS1+JMET12BS2N1+TXVAHRI reference: 215740367 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652724 → |
CTM24B5ABS1+JME08B2SN1AHRI reference: 215740372 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652729 → |
CTF24B5ABS1+JMET12BS2N1AHRI reference: 215740377 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652735 → |
CTF24B5ABS1+JMET08BS2N1AHRI reference: 215740389 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652739 → |
CTM24B5ABS1+JMC12B2SN1AHRI reference: 215740382 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652745 → |
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 215740384 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652747 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.