Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 7

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD60JXXN1+TXV+ furnace: TP9C120D20MP13AHRI reference: 21035339515.208.10300002.02EPA 4048908 →
XAHD60JBCN1+ furnace: TM9V120D20MP12AHRI reference: 21035340115.208.10300002.02EPA 4048915 →
XAHD60JBCN1+ furnace: TP9C120D20MP13AHRI reference: 21035340515.208.10300002.02EPA 4048919 →
XAHC60HBCN1+ furnace: TM8V120C20MP12AHRI reference: 21035686215.208.10308002.02EPA 4048926 →
XAHC60HBCN1+ furnace: TM8V100C20MP12AHRI reference: 21035686615.208.10308002.02EPA 4048930 →
XAHC60HBCN1+ furnace: TMLV120C20MP12AHRI reference: 21035687015.208.10308002.02EPA 4048935 →
XAHD60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035241115.208.10306002.00EPA 4048982 →
XAHD60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035241715.208.10306002.00EPA 4048986 →
XAFD60HXXN1+TXV+ furnace: TM9E120D20MP12AHRI reference: 21035541115.208.10314002.20EPA 4048991 →
XAFC60HBCN1+ furnace: TM9Y100C20MP11AHRI reference: 21035538515.208.10316002.22EPA 4048993 →
XAFD60HBCN1+ furnace: TM9E120D20MP12AHRI reference: 21035541715.208.10314002.20EPA 4049000 →
XAHD60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035542915.208.10308002.02EPA 4049006 →
XAFD60HXXN1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21241460015.208.10318002.32EPA 4049016 →
XAFD60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035679315.208.10314002.22EPA 4049017 →
XAFD60HXXN1+TXV+ furnace: TP9C120D20MP13AHRI reference: 21035345915.208.10308002.22EPA 4049028 →
XAFD60HBCN1+ furnace: TM9V120D20MP12AHRI reference: 21035346515.208.10308002.22EPA 4049034 →
XAFD60HBCN1+ furnace: TP9C120D20MP13AHRI reference: 21035347315.208.10308002.22EPA 4049038 →
XAFD60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241460515.208.10318002.32EPA 4049046 →
XAFD60HXXN1+TXV+ furnace: TM9V120D20MP12AHRI reference: 21035345515.208.10308002.22EPA 4049072 →
XAFD60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035351115.208.10314002.22EPA 4049118 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →