Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 6

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60JBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21035228315.208.10312002.18EPA 4048738 →
XAFC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035545515.208.10314002.22EPA 4048740 →
XAHC60HXXN1+TXV+ furnace: TM8V100C20MP12AHRI reference: 21035684315.208.10308002.02EPA 4048749 →
XAHC60HXXN1+TXV+ furnace: TMLV120C20MP12AHRI reference: 21035684715.208.10308002.02EPA 4048754 →
XAFC60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035546115.208.10314002.22EPA 4048757 →
XAFC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035348515.208.10310002.24EPA 4048782 →
XAFC60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035349115.208.10310002.24EPA 4048788 →
XAFD60HXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21035232915.208.10312002.18EPA 4048798 →
XAFD60HBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21035233515.208.10312002.18EPA 4048804 →
XAHC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035236715.208.10308002.02EPA 4048826 →
XAHC60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035237315.208.10308002.02EPA 4048832 →
XAFD60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035237915.208.10312002.20EPA 4048838 →
XAHC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035682515.208.10308002.02EPA 4048842 →
XAHC60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035683115.208.10308002.02EPA 4048848 →
XAFC60HXXN1+TXV+ furnace: TM9Y100C20MP11AHRI reference: 21035537915.208.10316002.22EPA 4048852 →
XAHC60HXXN1+TXV+ furnace: TM8V120C20MP12AHRI reference: 21035683915.208.10308002.02EPA 4048855 →
XAFD60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035238515.208.10312002.20EPA 4048862 →
XAFD60JXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035527915.208.10314002.22EPA 4048889 →
XAFD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035528515.208.10314002.22EPA 4048895 →
XAHD60JXXN1+TXV+ furnace: TM9V120D20MP12AHRI reference: 21035339115.208.10300002.02EPA 4048904 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →