Fraser-Johnston / AIR-SOURCE HEAT PUMP

HH836E2S12

LX SERIES

602 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.5BTU/Wh
Cooling capacity31,200–34,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 602 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18602 / 602
EER2 · BTU/Wh10–11.7602 / 602
HSPF2 · BTU/Wh8.5602 / 602
Cooling capacity · BTU/h31,200–34,000602 / 602
Heating capacity at 47°F / 8.3°C · BTU/h32,000–34,000602 / 602
Heating capacity at 17°F / −8.3°C · BTU/h32,600–34,200602 / 602
Heating capacity at 5°F / −15°C · BTU/h26,800–28,200602 / 602
COP at 5°F / −15°C2.18–2.38602 / 602
Equipment / loop typeHP - Split System602 / 602
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)602 / 602
Compressor stagingTwo-stage602 / 602
Connected capabilityNo602 / 602

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHC36C5CD2SS1Cold climate designationAHRI reference: 21859823518.008.50274002.30EPA 4651078 →
JHC42C5CF2SS1Cold climate designationAHRI reference: 21864420618.008.50268002.36EPA 4665969 →
CTF36C5CDS2+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21864379418.008.50280002.32EPA 4666381 →
CTF36C5CDS1+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21869868218.008.50280002.32EPA 4683838 →
CTM48C5CFS2+JME16C2SN2Cold climate designationAHRI reference: 21864440617.508.50268002.34EPA 4665769 →
CTM48C5CFS2+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 21864440217.508.50268002.34EPA 4665773 →
CTM48C5CFS2+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 21864439817.508.50270002.34EPA 4665777 →
CTU48C5XFS2+TXV+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21864439417.508.50270002.34EPA 4665781 →
CTF48C5CFS2+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21864439017.508.50270002.34EPA 4665785 →
CTU48C5XFS2+TXV+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 21864433417.508.50268002.36EPA 4665841 →
CTF48C5CFS2+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 21864433017.508.50268002.36EPA 4665845 →
CTU48C5XFS2+TXV+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21864421817.508.50270002.32EPA 4665957 →
CTF48C5CFS2+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21864421417.508.50270002.32EPA 4665961 →
CTM48C5CFS2+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 21864419017.508.50268002.34EPA 4665985 →
JHE42C5CF2SS2Cold climate designationAHRI reference: 21864418617.508.50270002.36EPA 4665989 →
CTM48C5CFS2+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 21864418217.508.50268002.32EPA 4665993 →
CTM48C5CFS2+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 21864417017.508.50268002.32EPA 4666005 →
CTM48C5CFS2+ furnace: Z8ET080C16LMPS1Cold climate designationAHRI reference: 21864416617.508.50268002.34EPA 4666009 →
CTM48C5CFS2+JME12C2SN2Cold climate designationAHRI reference: 21864411417.508.50270002.34EPA 4666061 →
CTU48C5XFS2+JME12C2SN2+TXVCold climate designationAHRI reference: 21864410217.508.50270002.34EPA 4666073 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →