Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 8

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD60JXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035526715.208.10300002.00EPA 4049123
XAHD60JBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035527315.208.10300002.00EPA 4049129
XAFD60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035679915.208.10314002.22EPA 4049134
XAFC60HXXN1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21241461515.208.10318002.32EPA 4049159
XAFD60JBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035530515.208.10314002.22EPA 4049161
XAFD60JBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035531115.208.10314002.22EPA 4049166
XAFD60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035352315.208.10314002.22EPA 4049171
XAFD60HBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247621615.208.10314002.34EPA 4049194
XAFD60JXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21247662415.208.10314002.38EPA 4049201
XAFC60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241462015.208.10318002.32EPA 4049210
XAFD60JBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241481015.208.10316002.32EPA 4049215
XAFD60JBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21247664515.208.10314002.36EPA 4049231
XAFC60HXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21247850315.208.10318002.32EPA 4049238
XAFC60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247851615.208.10318002.32EPA 4049245
XAFD60JBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21247663115.208.10314002.38EPA 4049263
XAFD60JXXN1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21247663815.208.10314002.36EPA 4049270
XAHD60JXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035880915.208.10300002.00EPA 4049294
XAHD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035881515.208.10300002.00EPA 4049298
XAHC60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035891315.208.10308002.02EPA 4049339
XAFD60JBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21241525415.208.10314002.38EPA 4049361

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →