XH624E2S11
LX SERIES · source records, page 3
58 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 58 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 58 / 58 |
| EER2 · BTU/Wh | 11.7–12 | 58 / 58 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 58 / 58 |
| Cooling capacity · BTU/h | 23,000–24,200 | 58 / 58 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–23,800 | 58 / 58 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 58 / 58 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 58 / 58 |
| COP at 5°F / −15°C | 2.1–2.3 | 58 / 58 |
| Equipment / loop type | HP - Split System | 58 / 58 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 58 / 58 |
| Compressor staging | Two-stage | 58 / 58 |
| Connected capability | No | 58 / 58 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36B5ADS1+ furnace: RG19080B12MPS1AHRI reference: 217020539 | 15.20 | 7.80 | 12400 | 2.22 | EPA 4571260 → |
CTM36B5ADS1+ furnace: RG19060B12MPS1AHRI reference: 217020537 | 15.20 | 8.10 | 12800 | 2.22 | EPA 4571261 → |
CTF36B5ADS1+ furnace: RG19060B12MPS1AHRI reference: 217020536 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4571262 → |
CTU36B5XDS1+TXV+ furnace: RG19060B12MPS1AHRI reference: 217020535 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4571263 → |
CTM36B5ADS1+ furnace: RL18080B12MPS1AHRI reference: 217020529 | 15.20 | 8.10 | 12400 | 2.26 | EPA 4571264 → |
CTM36B5ADS1+JMET08BS2N1AHRI reference: 217020528 | 15.20 | 7.80 | 11900 | 2.22 | EPA 4571265 → |
CTM36B5ADS1+JMET12BS2N1AHRI reference: 217020527 | 15.20 | 8.00 | 12000 | 2.24 | EPA 4571266 → |
CTU36B5XDS1+JMET08BS2N1+TXVAHRI reference: 217020518 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4571267 → |
CTF36B5ADS1+JMET08BS2N1AHRI reference: 217020517 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4571268 → |
CTM36B5ADS2+ furnace: RL18080B12MPS1AHRI reference: 218528544 | 15.20 | 8.10 | 12400 | 2.26 | EPA 4647522 → |
CTM36B5ADS2+ furnace: RG19060B12MPS1AHRI reference: 218528534 | 15.20 | 8.10 | 12800 | 2.22 | EPA 4647532 → |
CTM36B5ADS2+ furnace: RG19080B12MPS1AHRI reference: 218528528 | 15.20 | 7.80 | 12400 | 2.22 | EPA 4647538 → |
CTU36B5XDS2+TXV+ furnace: RG19060B12MPS1AHRI reference: 218528352 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4647660 → |
CTF36B5ADS2+ furnace: RG19060B12MPS1AHRI reference: 218528346 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4647666 → |
CTM36B5ADS2+JME12B2SN2AHRI reference: 218638228 | 15.20 | 8.00 | 12000 | 2.24 | EPA 4664411 → |
CTU36B5XDS2+JME08B2SN2+TXVAHRI reference: 218638216 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4664423 → |
CTF36B5ADS2+JME08B2SN2AHRI reference: 218638210 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4664429 → |
CTM36B5ADS2+JME08B2SN2AHRI reference: 218638162 | 15.20 | 7.80 | 11900 | 2.22 | EPA 4664453 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →