RH630E2S11
LX SERIES
19 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 19 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 19 / 19 |
| EER2 · BTU/Wh | 11.7–13 | 19 / 19 |
| HSPF2 · BTU/Wh | 8–8.1 | 19 / 19 |
| Cooling capacity · BTU/h | 29,600–30,800 | 19 / 19 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,000–29,800 | 19 / 19 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,800–19,800 | 19 / 19 |
| Heating capacity at 5°F / −15°C · BTU/h | 15,200–15,800 | 19 / 19 |
| COP at 5°F / −15°C | 2.26–2.4 | 19 / 19 |
| Equipment / loop type | HP - Split System | 19 / 19 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 19 / 19 |
| Compressor staging | Two-stage | 19 / 19 |
| Connected capability | No | 19 / 19 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36C5ADS2+ furnace: RL18080C16MPS1AHRI reference: 218530534 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4648344 → |
CTF36C5ADS2+ furnace: RL18100C16MPS1AHRI reference: 218530508 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4648370 → |
CTM36C5ADS2+ furnace: RL18100C16MPS1AHRI reference: 218530420 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4648446 → |
CTM36C5ADS2+ furnace: RL18080C16MPS1AHRI reference: 218530404 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4648462 → |
CTU36B5XDS2+TXV+ furnace: RL18080B12MPS1AHRI reference: 218530270 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4648596 → |
CTF36B5ADS2+ furnace: RL18080B12MPS1AHRI reference: 218530260 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4648606 → |
JHE30B5AD2SS1AHRI reference: 218416676 | 16.00 | 8.00 | 15400 | 2.36 | EPA 4608496 → |
CTM36B5ADS2+ furnace: RL18100B12MPS1AHRI reference: 218530550 | 16.00 | 8.10 | 15200 | 2.34 | EPA 4648328 → |
CTM36B5ADS2+ furnace: RG19060B12MPS1AHRI reference: 218530540 | 16.00 | 8.00 | 15800 | 2.26 | EPA 4648338 → |
CTF36C5ADS2+ furnace: RG19080C16MPS1AHRI reference: 218530514 | 16.00 | 8.10 | 15400 | 2.34 | EPA 4648364 → |
CTF36C5ADS2+ furnace: RL18080C20MPS1AHRI reference: 218530474 | 16.00 | 8.10 | 15200 | 2.36 | EPA 4648398 → |
CTM36C5ADS2+ furnace: RL18080C20MPS1AHRI reference: 218530456 | 16.00 | 8.10 | 15200 | 2.36 | EPA 4648416 → |
CTM36C5ADS2+ furnace: RG19080C16MPS1AHRI reference: 218530410 | 16.00 | 8.10 | 15400 | 2.32 | EPA 4648456 → |
CTU36B5XDS2+TXV+ furnace: RG19060B12MPS1AHRI reference: 218530378 | 16.00 | 8.10 | 15800 | 2.28 | EPA 4648488 → |
CTF36B5ADS2+ furnace: RG19060B12MPS1AHRI reference: 218530372 | 16.00 | 8.10 | 15800 | 2.28 | EPA 4648494 → |
CTU36B5XDS2+TXV+ furnace: RG19080B12MPS1AHRI reference: 218530366 | 16.00 | 8.10 | 15800 | 2.26 | EPA 4648500 → |
CTF36B5ADS2+ furnace: RG19080B12MPS1AHRI reference: 218530360 | 16.00 | 8.10 | 15800 | 2.26 | EPA 4648506 → |
CTU36B5XDS2+TXV+ furnace: RL18100B12MPS1AHRI reference: 218530318 | 16.00 | 8.10 | 15200 | 2.36 | EPA 4648548 → |
CTF36B5ADS2+ furnace: RL18100B12MPS1AHRI reference: 218530308 | 16.00 | 8.10 | 15200 | 2.36 | EPA 4648558 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →