Heating performance & equipment details
Ranges include the 10 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 10 / 10 |
| EER2 · BTU/Wh | 11.7–12 | 10 / 10 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 10 / 10 |
| Cooling capacity · BTU/h | 29,000 | 10 / 10 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 27,800–29,000 | 10 / 10 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,300–18,900 | 10 / 10 |
| Heating capacity at 5°F / −15°C · BTU/h | 15,600–18,600 | 10 / 10 |
| COP at 5°F / −15°C | 2.24–2.74 | 10 / 10 |
| Equipment / loop type | HP - Split System | 10 / 10 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 10 / 10 |
| Compressor staging | Two-stage | 10 / 10 |
| Connected capability | No | 10 / 10 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC36DBAN1+JME16C2SN1AHRI reference: 214801973 | 15.20 | 8.10 | 17900 | 2.68 | EPA 3559258 → |
XAFB36DBAN1+JME12B2SN1AHRI reference: 214801975 | 15.20 | 8.10 | 18600 | 2.74 | EPA 3559260 → |
XAFC36DBAN1+JME12C2SN1AHRI reference: 214801977 | 15.20 | 8.10 | 16500 | 2.50 | EPA 3559262 → |
XAFC48FBAN1+JME16C2SN1AHRI reference: 214811082 | 15.20 | 8.10 | 15800 | 2.40 | EPA 3560458 → |
XAFC48FBAN1+JME12C2SN1AHRI reference: 214811094 | 15.20 | 8.10 | 15800 | 2.42 | EPA 3560469 → |
XAFD48FBAN1+JME18D2SN1AHRI reference: 214811098 | 15.20 | 8.10 | 15600 | 2.40 | EPA 3560473 → |
XAFC36DBAN1+ furnace: RG19080C16MPS1AHRI reference: 214648076 | 15.20 | 7.80 | 15600 | 2.26 | EPA 3721882 → |
XAFB36DBAN1+ furnace: RG19080B12MPS1AHRI reference: 214648085 | 15.20 | 7.80 | 15800 | 2.26 | EPA 3721884 → |
XAFC48FBAN1+ furnace: RG19080C16MPS1AHRI reference: 214648145 | 15.20 | 7.80 | 15600 | 2.28 | EPA 3721885 → |
XAFB36DBAN1+ furnace: RG19060B12MPS1AHRI reference: 214648110 | 15.20 | 7.80 | 15700 | 2.24 | EPA 3721886 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.