EVCON / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 2

58 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,000–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 58 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1658 / 58
EER2 · BTU/Wh11.7–1258 / 58
HSPF2 · BTU/Wh7.8–8.158 / 58
Cooling capacity · BTU/h23,000–24,20058 / 58
Heating capacity at 47°F / 8.3°C · BTU/h22,600–23,80058 / 58
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,50058 / 58
Heating capacity at 5°F / −15°C · BTU/h11,900–12,80058 / 58
COP at 5°F / −15°C2.1–2.358 / 58
Equipment / loop typeHP - Split System58 / 58
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)58 / 58
Compressor stagingTwo-stage58 / 58
Connected capabilityNo58 / 58

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30C5ACS1+JMET12CS2N1AHRI reference: 21701704216.007.80123002.14EPA 4572044
CTF30C5ACS1+JMET16CS2N1AHRI reference: 21701702716.007.80123002.16EPA 4572048
CTF30B5ACS1+JME12B2SN1AHRI reference: 21701700716.007.80122002.14EPA 4572052
CTF30C5ACS1+JME12C2SN1AHRI reference: 21701695816.007.80122002.16EPA 4572066
CTF30C5ACS1+JME16C2SN1AHRI reference: 21701695416.007.80122002.16EPA 4572070
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 21701687816.007.80122002.14EPA 4572090
JHE30B5AD2SS2AHRI reference: 21845722616.008.10121002.26EPA 4639460
JHE24B5AC2SS2AHRI reference: 21845722016.008.00120002.12EPA 4639466
CTM36B5ADS2+ furnace: RL18100B12MPS1AHRI reference: 21852851416.008.10125002.26EPA 4647552
CTM30B5ACS2+ furnace: RL18100B12MPS1AHRI reference: 21852847616.007.80125002.10EPA 4647574
CTU36B5XDS2+TXV+ furnace: RL18100B12MPS1AHRI reference: 21852837216.008.10125002.28EPA 4647640
CTF36B5ADS2+ furnace: RL18100B12MPS1AHRI reference: 21852836216.008.10125002.28EPA 4647650
CTU36B5XDS2+TXV+ furnace: RL18080B12MPS1AHRI reference: 21852834016.008.10124002.28EPA 4647672
CTF36B5ADS2+ furnace: RL18080B12MPS1AHRI reference: 21852833016.008.10124002.28EPA 4647682
CTU36B5XDS2+TXV+ furnace: RG19080B12MPS1AHRI reference: 21852832016.008.10124002.24EPA 4647692
CTF36B5ADS2+ furnace: RG19080B12MPS1AHRI reference: 21852831416.008.10124002.24EPA 4647698
CTF30C5ACS2+JME12C2SN2AHRI reference: 21863822216.007.80123002.14EPA 4664417
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 21863818616.008.00120002.26EPA 4664435
CTF36B5ADS2+JME12B2SN2AHRI reference: 21863818016.008.00120002.26EPA 4664441
CTF30C5ACS2+JME16C2SN2AHRI reference: 21863817416.007.80123002.16EPA 4664447

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →