Breeze33 / AIR-SOURCE HEAT PUMP

7HP14F24P-**A

7HP14F Series · source records, page 3

108 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 108 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16108 / 108
EER2 · BTU/Wh12.8–13.8108 / 108
HSPF2 · BTU/Wh7.8–8.2108 / 108
Cooling capacity · BTU/h23,000–24,000108 / 108
Heating capacity at 47°F / 8.3°C · BTU/h21,400–23,000108 / 108
Heating capacity at 17°F / −8.3°C · BTU/h13,700–14,700108 / 108
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600108 / 108
COP at 5°F / −15°C1.96–2.2108 / 108
Equipment / loop typeHP - Split System108 / 108
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)108 / 108
Compressor stagingSingle stage108 / 108
Connected capabilityNo108 / 108

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH24AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21579242015.507.80105001.96EPA 3653542
7EH30AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21579244615.507.80109002.04EPA 3653547
7EH30BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21579245815.508.00110002.08EPA 3653592
7E[C,U]30BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21579240615.508.10114002.16EPA 3653593
7EH30BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21579246715.508.00111002.06EPA 3653596
7E[C,U]30BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21579241215.508.10114002.18EPA 3653599
7E[C,U]30BX-**+TDR+ furnace: 97G2UH045BV12*AHRI reference: 21649875415.508.00113002.14EPA 3847460
7EH30BX-**+TDR+ furnace: 97G2UH045BV12*AHRI reference: 21649875615.507.80109002.06EPA 3847462
7E[C,U]24BX-**+TDR+ furnace: 97G2UH045BV12*AHRI reference: 21649875315.507.80108002.02EPA 3847494
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AV12*AHRI reference: 21677926615.508.00114002.14EPA 3992873
7E[C,U]30BX-**+TDR+ furnace: 97G2UH070BV12*AHRI reference: 21677926915.508.00113002.16EPA 3992876
7EH24BX-**+TDR+ furnace: 97G2UH070BV12*AHRI reference: 21677927415.508.10106002.00EPA 3992881
7E[C,U]30BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21579241415.208.00116002.14EPA 3653360
7E[C,U]30BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21579241515.208.10115002.14EPA 3653361
7ED30/36CX-**+TDR+ furnace: 92G1DF090CE16*AHRI reference: 21579248115.208.20114002.12EPA 3653393
7ED30/36CX-**+TDR+ furnace: 96G1DF090CE16*AHRI reference: 21579248215.208.20113002.12EPA 3653394
7EH30AX-**+TDR+ furnace: 80G1UH045AE12*AHRI reference: 21579244915.207.80109002.02EPA 3653402
7EH30AX-**+TDR+ furnace: 80G1UH045AE12L*AHRI reference: 21579245015.207.80109002.02EPA 3653403
7EH30AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21579245115.208.00110002.04EPA 3653404
7EH30AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21579245215.207.80110002.04EPA 3653405

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →