Breeze33 / AIR-SOURCE HEAT PUMP

7HP14F24P-**A

7HP14F Series · source records, page 4

108 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 108 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16108 / 108
EER2 · BTU/Wh12.8–13.8108 / 108
HSPF2 · BTU/Wh7.8–8.2108 / 108
Cooling capacity · BTU/h23,000–24,000108 / 108
Heating capacity at 47°F / 8.3°C · BTU/h21,400–23,000108 / 108
Heating capacity at 17°F / −8.3°C · BTU/h13,700–14,700108 / 108
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600108 / 108
COP at 5°F / −15°C1.96–2.2108 / 108
Equipment / loop typeHP - Split System108 / 108
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)108 / 108
Compressor stagingSingle stage108 / 108
Connected capabilityNo108 / 108

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21579245915.207.80112002.04EPA 3653407
7EH30BX-**+TDR+ furnace: 97G2UH070BE12*AHRI reference: 21579246015.207.80112002.04EPA 3653408
7E[C,U]30BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21579240115.208.00115002.12EPA 3653414
7AH1AE24PX-**AHRI reference: 21579235715.207.80110002.06EPA 3653429
7EH30BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21579245315.208.00111002.06EPA 3653431
7EH30BX-**+TDR+ furnace: 95G1UH040BE12X*AHRI reference: 21579245415.207.80112002.04EPA 3653432
7EH30BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21579245515.208.00112002.04EPA 3653433
7E[C,U]24BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21579237815.207.80110002.02EPA 3653442
7EH24BX-**+TDR+ furnace: 92G1UH030BE12*AHRI reference: 21579243915.207.80105001.96EPA 3653453
7AH2AE24PX-**AHRI reference: 21579236215.208.20112002.16EPA 3653476
7E[C,U]24AX-**+TDR+ furnace: 80G1UH040AE12X*AHRI reference: 21579236615.207.80110002.02EPA 3653479
7E[C,U]24AX-**+TDR+ furnace: 80G2UH070AE12*AHRI reference: 21579236915.207.80110002.02EPA 3653498
7E[C,U]24BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21579238815.207.80110002.02EPA 3653506
7E[C,U]24BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21579238915.207.80110002.04EPA 3653507
7E[C,U]24BX-**+TDR+ furnace: 96G1UH070BE12*AHRI reference: 21579239115.207.80110002.04EPA 3653508
7E[C,U]30AX-**+TDR+ furnace: 80G1UH040AE12X*AHRI reference: 21579239215.208.00115002.14EPA 3653509
7EH24AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21579242515.207.80107001.98EPA 3653510
7EH24AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21579242615.207.80107001.98EPA 3653511
7EH24BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21579242715.208.00108001.98EPA 3653512
7EH24BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21579243015.207.80105001.98EPA 3653513

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.