Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2198 / 198
EER2 · BTU/Wh12.2–13.5198 / 198
HSPF2 · BTU/Wh7.8–8.6198 / 198
Cooling capacity · BTU/h28,200–30,600198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600198 / 198
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400198 / 198
COP at 5°F / −15°C1.96–2.36198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-410A (GWP:2088)198 / 198
Compressor stagingSingle stage198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21331548116.208.10141002.26EPA 2840710
EAD4X-42B+TDR+ furnace: 80G1DF090BE16AHRI reference: 21331553216.208.60148002.34EPA 2840778
EAC4X36B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21331551916.208.10141002.26EPA 2840982
EAH1P36C*+TDR+TXV+ furnace: 80G1UH100CE20XAHRI reference: 21331554716.208.00138002.10EPA 2840990
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470877416.208.10141002.28EPA 3491729
7ED42BX-0*+TDR+ furnace: 80G1DF090BE16AHRI reference: 21470872216.208.60148002.34EPA 3494320
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470868616.207.80134002.10EPA 3494337
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21470868716.207.80134002.10EPA 3494339
7EH30BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470867716.208.00135002.12EPA 3494381
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470877516.208.10141002.28EPA 3494479
7EC36BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470878216.208.10141002.26EPA 3494535
7EC36BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21470878316.208.10141002.26EPA 3494536
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470867816.207.80134002.12EPA 3494582
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470867916.207.80134002.12EPA 3494583
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470868416.207.80134002.12EPA 3494590
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470868516.207.80134002.12EPA 3494591
7EC36BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470877316.208.10143002.30EPA 3543727
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21331547716.008.10144002.28EPA 2840707
EA(C;U)1P36B+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21331547916.008.10143002.26EPA 2840708
EAC4X30B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21331550016.008.00142002.22EPA 2840767

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →