Breeze33 / AIR-SOURCE HEAT PUMP

7HP14F24P-**A

7HP14F Series · source records, page 2

108 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 108 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16108 / 108
EER2 · BTU/Wh12.8–13.8108 / 108
HSPF2 · BTU/Wh7.8–8.2108 / 108
Cooling capacity · BTU/h23,000–24,000108 / 108
Heating capacity at 47°F / 8.3°C · BTU/h21,400–23,000108 / 108
Heating capacity at 17°F / −8.3°C · BTU/h13,700–14,700108 / 108
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600108 / 108
COP at 5°F / −15°C1.96–2.2108 / 108
Equipment / loop typeHP - Split System108 / 108
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)108 / 108
Compressor stagingSingle stage108 / 108
Connected capabilityNo108 / 108

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH1AV30PX-**AHRI reference: 21579236115.508.10116002.08EPA 3653474 →
7AH2AE30PX-**AHRI reference: 21579236315.508.20114002.20EPA 3653477 →
7AH2AV30PXC**AHRI reference: 21579236515.508.20114002.20EPA 3653478 →
7E[C,U]24AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21579236815.507.80107002.04EPA 3653481 →
7E[C,U]24BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21579238015.508.00109002.06EPA 3653487 →
7E[C,U]24BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21579238315.507.80108002.04EPA 3653488 →
7E[C,U]24BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21579238415.507.80108002.04EPA 3653489 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH045AE12L*AHRI reference: 21579237215.507.80106002.00EPA 3653499 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21579237315.507.80108002.04EPA 3653500 →
7E[C,U]24AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21579237415.507.80108002.04EPA 3653501 →
7E[C,U]24BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21579238515.508.00108002.04EPA 3653503 →
7E[C,U]24BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21579238615.508.00108002.04EPA 3653504 →
7E[C,U]24BX-**+TDR+ furnace: 92G1UH030BE12*AHRI reference: 21579238715.507.80106002.00EPA 3653505 →
7EH24BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21579243115.508.10108002.02EPA 3653514 →
7EH24BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21579243215.508.10107002.00EPA 3653515 →
7E[C,U]30AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21579239415.508.00112002.16EPA 3653528 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH045AE12*AHRI reference: 21579239715.507.80112002.14EPA 3653531 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH045AE12L*AHRI reference: 21579239815.507.80112002.14EPA 3653532 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21579239915.508.00113002.14EPA 3653533 →
7E[C,U]30AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21579240015.508.00113002.14EPA 3653534 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →