YH548E2S11
LX SERIES · source records, page 7
381 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 381 / 381 |
| EER2 · BTU/Wh | 11–12 | 381 / 381 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 381 / 381 |
| Cooling capacity · BTU/h | 45,500–48,000 | 381 / 381 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 381 / 381 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 381 / 381 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 381 / 381 |
| COP at 5°F / −15°C | 2.1–2.42 | 381 / 381 |
| Equipment / loop type | HP - Split System | 381 / 381 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 381 / 381 |
| Compressor staging | Two-stage | 381 / 381 |
| Connected capability | No | 381 / 381 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CGS1+JMVT20DC2N1AHRI reference: 214425337 | 15.20 | 7.80 | 24600 | 2.28 | EPA 3991983 → |
CTF60C5CHS1+ furnace: Y81E080C16SMPS1AHRI reference: 214425511 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3991984 → |
CTF60C5CHS1+ furnace: Y81E100C16SMPS1AHRI reference: 214425505 | 15.20 | 7.80 | 26000 | 2.38 | EPA 3991985 → |
CTF60C5CHS1+JMET16CS2N1AHRI reference: 214425538 | 15.20 | 8.10 | 26200 | 2.38 | EPA 3991986 → |
CTF60D5CGS1+JMET18DS2N1AHRI reference: 214425571 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3991987 → |
CTF60D5CHS1+ furnace: Y92E120D20SMPS1AHRI reference: 216376745 | 15.20 | 7.80 | 26000 | 2.38 | EPA 3992208 → |
CTF60C5CHS1+ furnace: Y92E100C16SMPS1AHRI reference: 216376737 | 15.20 | 7.80 | 26600 | 2.34 | EPA 3992209 → |
CTF60C5CHS1+ furnace: Y92E080C16SMPS1AHRI reference: 216376742 | 15.20 | 7.80 | 26200 | 2.34 | EPA 3992210 → |
CTF60C5CHS1+ furnace: Y92E100C20SMPS1AHRI reference: 216376740 | 15.20 | 7.80 | 26400 | 2.34 | EPA 3992211 → |
CTU60D5XHS1+TXV+ furnace: Y92E120D20SMPS1AHRI reference: 216376748 | 15.20 | 7.80 | 26000 | 2.38 | EPA 3992214 → |
CTF60C5CHS1+ furnace: Y91E080C20SMPS1AHRI reference: 214605036 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992258 → |
CTF60D5CHS1+ furnace: Y91E120D20SMPS1AHRI reference: 214605040 | 15.20 | 7.80 | 25800 | 2.38 | EPA 3992259 → |
CTU60D5XHS1+TXV+ furnace: Y81E130D20SMPS1AHRI reference: 214650207 | 15.20 | 8.10 | 26600 | 2.38 | EPA 3992364 → |
CTU60D5XHS1+TXV+ furnace: Y91E120D20SMPS1AHRI reference: 214650277 | 15.20 | 7.80 | 25800 | 2.38 | EPA 3992365 → |
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 214807422 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992563 → |
CTU60D5XGS1+JMC20D2SN1+TXVAHRI reference: 214807420 | 15.20 | 7.80 | 24600 | 2.28 | EPA 3992565 → |
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 214807463 | 15.20 | 8.10 | 26000 | 2.40 | EPA 3992567 → |
CTU60C5XGS1+JME16C2SN1+TXVAHRI reference: 214807421 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992568 → |
CTU60D5XGS1+JMET18DS2N1+TXVAHRI reference: 214807426 | 15.20 | 7.80 | 25000 | 2.26 | EPA 3992569 → |
CTU60D5XGS1+JMVT20DC2N1+TXVAHRI reference: 214807417 | 15.20 | 7.80 | 24600 | 2.28 | EPA 3992570 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →