York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 7

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CGS1+JMVT20DC2N1AHRI reference: 21442533715.207.80246002.28EPA 3991983 →
CTF60C5CHS1+ furnace: Y81E080C16SMPS1AHRI reference: 21442551115.207.80262002.36EPA 3991984 →
CTF60C5CHS1+ furnace: Y81E100C16SMPS1AHRI reference: 21442550515.207.80260002.38EPA 3991985 →
CTF60C5CHS1+JMET16CS2N1AHRI reference: 21442553815.208.10262002.38EPA 3991986 →
CTF60D5CGS1+JMET18DS2N1AHRI reference: 21442557115.207.80250002.26EPA 3991987 →
CTF60D5CHS1+ furnace: Y92E120D20SMPS1AHRI reference: 21637674515.207.80260002.38EPA 3992208 →
CTF60C5CHS1+ furnace: Y92E100C16SMPS1AHRI reference: 21637673715.207.80266002.34EPA 3992209 →
CTF60C5CHS1+ furnace: Y92E080C16SMPS1AHRI reference: 21637674215.207.80262002.34EPA 3992210 →
CTF60C5CHS1+ furnace: Y92E100C20SMPS1AHRI reference: 21637674015.207.80264002.34EPA 3992211 →
CTU60D5XHS1+TXV+ furnace: Y92E120D20SMPS1AHRI reference: 21637674815.207.80260002.38EPA 3992214 →
CTF60C5CHS1+ furnace: Y91E080C20SMPS1AHRI reference: 21460503615.207.80258002.36EPA 3992258 →
CTF60D5CHS1+ furnace: Y91E120D20SMPS1AHRI reference: 21460504015.207.80258002.38EPA 3992259 →
CTU60D5XHS1+TXV+ furnace: Y81E130D20SMPS1AHRI reference: 21465020715.208.10266002.38EPA 3992364 →
CTU60D5XHS1+TXV+ furnace: Y91E120D20SMPS1AHRI reference: 21465027715.207.80258002.38EPA 3992365 →
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 21480742215.207.80250002.26EPA 3992563 →
CTU60D5XGS1+JMC20D2SN1+TXVAHRI reference: 21480742015.207.80246002.28EPA 3992565 →
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 21480746315.208.10260002.40EPA 3992567 →
CTU60C5XGS1+JME16C2SN1+TXVAHRI reference: 21480742115.207.80250002.26EPA 3992568 →
CTU60D5XGS1+JMET18DS2N1+TXVAHRI reference: 21480742615.207.80250002.26EPA 3992569 →
CTU60D5XGS1+JMVT20DC2N1+TXVAHRI reference: 21480741715.207.80246002.28EPA 3992570 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.