York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 8

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 21480746415.208.10262002.42EPA 3992573 →
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 21480746615.208.10260002.42EPA 3992577 →
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 21480746515.208.10262002.42EPA 3992578 →
CTM60C5CHS1+ furnace: Y81E100C20LMPS1AHRI reference: 21678064215.208.10262002.40EPA 4046768 →
CTM60C5CHS1+ furnace: Y81E080C20LMPS1AHRI reference: 21677992015.208.10262002.40EPA 4046778 →
CTM60C5CHS1+ furnace: Y81E120C20LMPS1AHRI reference: 21678077915.208.10262002.38EPA 4046784 →
CTF60C5CHS1+ furnace: Y81E120C16LMPS1AHRI reference: 21678092815.208.10264002.36EPA 4046788 →
CTF60C5CHS1+ furnace: Y81E100C20LMPS1AHRI reference: 21678034615.208.10262002.38EPA 4046865 →
CTF60D5CHS1+ furnace: Y81E130D20LMPS1AHRI reference: 21678035115.208.10266002.38EPA 4046866 →
CTU60D5XHS1+TXV+ furnace: Y81E130D20LMPS1AHRI reference: 21678035615.208.10266002.38EPA 4046867 →
CTM60C5CHS1+ furnace: Y81E120C16LMPS1AHRI reference: 21677970915.208.10264002.38EPA 4046873 →
CTM60C5CHS1+ furnace: Y81E100C16LMPS1AHRI reference: 21677971415.208.10266002.36EPA 4046874 →
CTM60D5CHS1+ furnace: Y81E130D20LMPS1AHRI reference: 21677972015.208.10264002.40EPA 4046875 →
CTF60C5CHS1+ furnace: Y82V080C16SMPC1AHRI reference: 21744470715.207.80262002.38EPA 4570498 →
CTF60C5CHS1+ furnace: Y82V100C16SMPC1AHRI reference: 21744470515.207.80262002.38EPA 4570500 →
CTF60C5CHS1+ furnace: Y82V100C20SMPC1AHRI reference: 21744470215.207.80264002.40EPA 4570503 →
CTU60C5XGS1+TXV+ furnace: Y82V120C20SMPC1AHRI reference: 21744469815.207.80256002.28EPA 4570506 →
CTF60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 21744469715.207.80256002.28EPA 4570507 →
CTM60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 21744469115.207.80256002.28EPA 4570508 →
CTU60C5XGS1+TXV+ furnace: Y82V100C20SMPC1AHRI reference: 21744469015.207.80258002.26EPA 4570509 →