YH548E2S11
LX SERIES · source records, page 8
381 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 381 / 381 |
| EER2 · BTU/Wh | 11–12 | 381 / 381 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 381 / 381 |
| Cooling capacity · BTU/h | 45,500–48,000 | 381 / 381 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 381 / 381 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 381 / 381 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 381 / 381 |
| COP at 5°F / −15°C | 2.1–2.42 | 381 / 381 |
| Equipment / loop type | HP - Split System | 381 / 381 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 381 / 381 |
| Compressor staging | Two-stage | 381 / 381 |
| Connected capability | No | 381 / 381 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 214807464 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3992573 → |
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 214807466 | 15.20 | 8.10 | 26000 | 2.42 | EPA 3992577 → |
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 214807465 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3992578 → |
CTM60C5CHS1+ furnace: Y81E100C20LMPS1AHRI reference: 216780642 | 15.20 | 8.10 | 26200 | 2.40 | EPA 4046768 → |
CTM60C5CHS1+ furnace: Y81E080C20LMPS1AHRI reference: 216779920 | 15.20 | 8.10 | 26200 | 2.40 | EPA 4046778 → |
CTM60C5CHS1+ furnace: Y81E120C20LMPS1AHRI reference: 216780779 | 15.20 | 8.10 | 26200 | 2.38 | EPA 4046784 → |
CTF60C5CHS1+ furnace: Y81E120C16LMPS1AHRI reference: 216780928 | 15.20 | 8.10 | 26400 | 2.36 | EPA 4046788 → |
CTF60C5CHS1+ furnace: Y81E100C20LMPS1AHRI reference: 216780346 | 15.20 | 8.10 | 26200 | 2.38 | EPA 4046865 → |
CTF60D5CHS1+ furnace: Y81E130D20LMPS1AHRI reference: 216780351 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4046866 → |
CTU60D5XHS1+TXV+ furnace: Y81E130D20LMPS1AHRI reference: 216780356 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4046867 → |
CTM60C5CHS1+ furnace: Y81E120C16LMPS1AHRI reference: 216779709 | 15.20 | 8.10 | 26400 | 2.38 | EPA 4046873 → |
CTM60C5CHS1+ furnace: Y81E100C16LMPS1AHRI reference: 216779714 | 15.20 | 8.10 | 26600 | 2.36 | EPA 4046874 → |
CTM60D5CHS1+ furnace: Y81E130D20LMPS1AHRI reference: 216779720 | 15.20 | 8.10 | 26400 | 2.40 | EPA 4046875 → |
CTF60C5CHS1+ furnace: Y82V080C16SMPC1AHRI reference: 217444707 | 15.20 | 7.80 | 26200 | 2.38 | EPA 4570498 → |
CTF60C5CHS1+ furnace: Y82V100C16SMPC1AHRI reference: 217444705 | 15.20 | 7.80 | 26200 | 2.38 | EPA 4570500 → |
CTF60C5CHS1+ furnace: Y82V100C20SMPC1AHRI reference: 217444702 | 15.20 | 7.80 | 26400 | 2.40 | EPA 4570503 → |
CTU60C5XGS1+TXV+ furnace: Y82V120C20SMPC1AHRI reference: 217444698 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570506 → |
CTF60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 217444697 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570507 → |
CTM60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 217444691 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570508 → |
CTU60C5XGS1+TXV+ furnace: Y82V100C20SMPC1AHRI reference: 217444690 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4570509 → |