York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 6

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS1+ furnace: TL8E100C20UH11AHRI reference: 21442490815.207.80258002.38EPA 3991959 →
CTF60C5CHS1+JMC16C2SN1AHRI reference: 21442490615.207.80262002.40EPA 3991960 →
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 21442490415.207.80262002.40EPA 3991961 →
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 21442501515.208.10262002.42EPA 3991963 →
CTM60C5CHS1+ furnace: TM9V100C16MP12AHRI reference: 21442508915.207.80260002.36EPA 3991964 →
CTM60C5CHS1+ furnace: TP9C100C16MP13AHRI reference: 21442509115.207.80260002.36EPA 3991965 →
CTM60C5CHS1+ furnace: YP9C100C16MP13AHRI reference: 21442509315.207.80260002.36EPA 3991966 →
CTF60D5CHS1+JMET18DS2N1AHRI reference: 21442511015.208.10260002.40EPA 3991967 →
CTF60C5CGS1+JME16C2SN1AHRI reference: 21442512515.207.80250002.26EPA 3991969 →
CTM60C5CHS1+ furnace: TM8V100C20MP12AHRI reference: 21442514915.207.80258002.36EPA 3991970 →
CTF60C5CHS1+ furnace: Y81E120C20SMPS1AHRI reference: 21442514515.207.80262002.36EPA 3991971 →
CTM60C5CHS1+ furnace: TM8V120C20MP12AHRI reference: 21442514715.207.80258002.36EPA 3991972 →
CTM60C5CHS1+ furnace: TPLC100C20MP13AHRI reference: 21442515315.207.80258002.36EPA 3991974 →
CTM60C5CHS1+ furnace: TPLC120C20MP13AHRI reference: 21442515515.207.80258002.36EPA 3991975 →
CTM60C5CHS1+ furnace: YPLC120C20MP13AHRI reference: 21442515915.207.80258002.36EPA 3991976 →
CTM60C5CHS1+ furnace: YPLC100C20MP13AHRI reference: 21442515715.207.80258002.36EPA 3991977 →
CTF60C5CHS1+JME16C2SN1AHRI reference: 21442519715.208.10260002.40EPA 3991978 →
CTF60C5CHS1+ furnace: Y81E100C20SMPS1AHRI reference: 21442516315.208.10262002.38EPA 3991979 →
CTF60D5CHS1+ furnace: Y81E130D20SMPS1AHRI reference: 21442527815.208.10266002.38EPA 3991980 →
CTF60D5CGS1+JME18D2SN1AHRI reference: 21442539715.207.80250002.26EPA 3991982 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →