York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 6

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS1+ furnace: TL8E100C20UH11AHRI reference: 21442490815.207.80258002.38EPA 3991959
CTF60C5CHS1+JMC16C2SN1AHRI reference: 21442490615.207.80262002.40EPA 3991960
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 21442490415.207.80262002.40EPA 3991961
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 21442501515.208.10262002.42EPA 3991963
CTM60C5CHS1+ furnace: TM9V100C16MP12AHRI reference: 21442508915.207.80260002.36EPA 3991964
CTM60C5CHS1+ furnace: TP9C100C16MP13AHRI reference: 21442509115.207.80260002.36EPA 3991965
CTM60C5CHS1+ furnace: YP9C100C16MP13AHRI reference: 21442509315.207.80260002.36EPA 3991966
CTF60D5CHS1+JMET18DS2N1AHRI reference: 21442511015.208.10260002.40EPA 3991967
CTF60C5CGS1+JME16C2SN1AHRI reference: 21442512515.207.80250002.26EPA 3991969
CTM60C5CHS1+ furnace: TM8V100C20MP12AHRI reference: 21442514915.207.80258002.36EPA 3991970
CTF60C5CHS1+ furnace: Y81E120C20SMPS1AHRI reference: 21442514515.207.80262002.36EPA 3991971
CTM60C5CHS1+ furnace: TM8V120C20MP12AHRI reference: 21442514715.207.80258002.36EPA 3991972
CTM60C5CHS1+ furnace: TPLC100C20MP13AHRI reference: 21442515315.207.80258002.36EPA 3991974
CTM60C5CHS1+ furnace: TPLC120C20MP13AHRI reference: 21442515515.207.80258002.36EPA 3991975
CTM60C5CHS1+ furnace: YPLC120C20MP13AHRI reference: 21442515915.207.80258002.36EPA 3991976
CTM60C5CHS1+ furnace: YPLC100C20MP13AHRI reference: 21442515715.207.80258002.36EPA 3991977
CTF60C5CHS1+JME16C2SN1AHRI reference: 21442519715.208.10260002.40EPA 3991978
CTF60C5CHS1+ furnace: Y81E100C20SMPS1AHRI reference: 21442516315.208.10262002.38EPA 3991979
CTF60D5CHS1+ furnace: Y81E130D20SMPS1AHRI reference: 21442527815.208.10266002.38EPA 3991980
CTF60D5CGS1+JME18D2SN1AHRI reference: 21442539715.207.80250002.26EPA 3991982

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →