Trane / AIR-SOURCE HEAT PUMP

5TWX6042A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 9

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity38,500–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16188 / 188
EER2 · BTU/Wh11.7–12188 / 188
HSPF2 · BTU/Wh7.8–8.1188 / 188
Cooling capacity · BTU/h38,500–41,500188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,500188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,000188 / 188
Heating capacity at 5°F / −15°C · BTU/h18,700–19,800188 / 188
COP at 5°F / −15°C2.11–2.3188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingSingle stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D010AS3+TSTATAHRI reference: 21811303815.208.10198002.12EPA 4575809
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21815940815.208.10192002.20EPA 4576552
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21815940415.208.00193002.14EPA 4576556
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21815940315.207.80192002.16EPA 4576557
5PX*C007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21839639115.208.10194002.15EPA 4599161
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21839639015.208.10195002.14EPA 4599162
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839637815.208.10195002.13EPA 4599167
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21839637415.208.10194002.16EPA 4599169
5TXCD008AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21839626015.208.10194002.14EPA 4599197
5TXCD008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21839625915.208.10195002.15EPA 4599198
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21839625415.208.10194002.14EPA 4599201
5TXCC007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21839625315.208.10194002.16EPA 4599202
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21839624415.208.10194002.14EPA 4599203
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21839624315.208.10196002.12EPA 4599204
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21839624215.208.10196002.12EPA 4599205
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21839623815.208.10194002.16EPA 4599207
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21839623715.208.10194002.16EPA 4599208
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21839623515.208.10194002.16EPA 4599210
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21839623415.208.10194002.16EPA 4599211
5PX*D008AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21839623315.208.10194002.14EPA 4599212

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.