Trane / AIR-SOURCE HEAT PUMP

5TWX6042A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 10

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity38,500–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16188 / 188
EER2 · BTU/Wh11.7–12188 / 188
HSPF2 · BTU/Wh7.8–8.1188 / 188
Cooling capacity · BTU/h38,500–41,500188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,500188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,000188 / 188
Heating capacity at 5°F / −15°C · BTU/h18,700–19,800188 / 188
COP at 5°F / −15°C2.11–2.3188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingSingle stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21839623215.208.10195002.15EPA 4599213
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839622215.208.10193002.15EPA 4599218
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839621815.208.10193002.15EPA 4599222
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21839621715.208.10195002.14EPA 4599223
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21839621015.208.10195002.14EPA 4599224
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21839620915.208.00193002.16EPA 4599225
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21839620815.208.10195002.14EPA 4599226
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21839620715.208.10195002.14EPA 4599227

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →