Trane / AIR-SOURCE HEAT PUMP

5TWX6042A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 4

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity38,500–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16188 / 188
EER2 · BTU/Wh11.7–12188 / 188
HSPF2 · BTU/Wh7.8–8.1188 / 188
Cooling capacity · BTU/h38,500–41,500188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,500188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,000188 / 188
Heating capacity at 5°F / −15°C · BTU/h18,700–19,800188 / 188
COP at 5°F / −15°C2.11–2.3188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingSingle stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811065716.008.10191002.20EPA 4575214
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21811065616.008.10194002.14EPA 4575215
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21811065516.008.10194002.14EPA 4575216
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21811064616.008.10194002.14EPA 4575225
5TXCD010AS3+TSTAT+P0V0D000M50SDAHRI reference: 21811082816.008.00189002.26EPA 4575790
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21811082516.008.10191002.22EPA 4575793
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21811082416.008.10191002.22EPA 4575794
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21811082316.008.10191002.22EPA 4575795
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21811082216.008.10191002.22EPA 4575796
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21811082116.008.10191002.21EPA 4575797
5TXCD008AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21811081916.008.10193002.16EPA 4575799
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811081816.008.10193002.15EPA 4575800
5TXCD008AS3+TSTAT+P0V0D000M50SDAHRI reference: 21811081716.008.10190002.19EPA 4575801
5TXCD008AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21811081616.008.10193002.16EPA 4575802
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811081516.008.10193002.15EPA 4575803
5TXCD008AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21811081416.008.10192002.17EPA 4575804
5TXCD008AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21811081316.008.10192002.17EPA 4575805
5TXCD008AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21811081216.008.10192002.17EPA 4575806
5TXCD008AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21811081116.008.10192002.17EPA 4575807
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21815940716.008.10192002.20EPA 4576553

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →