Trane / AIR-SOURCE HEAT PUMP

5TWX6042A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 3

188 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity38,500–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX6042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16188 / 188
EER2 · BTU/Wh11.7–12188 / 188
HSPF2 · BTU/Wh7.8–8.1188 / 188
Cooling capacity · BTU/h38,500–41,500188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,500188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,000188 / 188
Heating capacity at 5°F / −15°C · BTU/h18,700–19,800188 / 188
COP at 5°F / −15°C2.11–2.3188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingSingle stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811070216.008.10193002.15EPA 4575192
5PX*CD09AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811069816.008.00192002.15EPA 4575193
5PX*CD09AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811069716.008.00192002.15EPA 4575194
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811069416.008.00192002.15EPA 4575195
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811069316.008.00192002.15EPA 4575196
5PX*CD09AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811069216.008.00189002.19EPA 4575197
5PX*C009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811067316.008.10192002.20EPA 4575198
5PX*C009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811067216.008.10192002.20EPA 4575199
5PX*C009AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21811067116.008.10193002.20EPA 4575200
5PX*C009AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21811067016.008.10193002.20EPA 4575201
5PX*C009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811066816.008.10192002.20EPA 4575203
5PX*C009AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21811066716.008.10193002.20EPA 4575204
5PX*C009AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21811066616.008.10193002.20EPA 4575205
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811066516.008.10191002.21EPA 4575206
5PX*C009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21811066416.008.10190002.22EPA 4575207
5PX*C009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811066316.008.10190002.24EPA 4575208
5PX*C009AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21811066216.008.10192002.20EPA 4575209
5PX*C009AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21811066116.008.10192002.20EPA 4575210
5PX*C009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811066016.008.10192002.20EPA 4575211
5PX*C009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811065916.008.10191002.20EPA 4575212

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →