SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,000–35,400BTU/h

Each efficiency range summarizes published EPA records for 5TWX6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 374 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5374 / 374
EER2 · BTU/Wh11.2–12374 / 374
HSPF2 · BTU/Wh7.8–8.1374 / 374
Cooling capacity · BTU/h32,000–35,400374 / 374
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,400374 / 374
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200374 / 374
Heating capacity at 5°F / −15°C · BTU/h16,900–17,700374 / 374
COP at 5°F / −15°C2.22–2.48374 / 374
Equipment / loop typeHP - Split System374 / 374
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)374 / 374
Compressor stagingSingle stage374 / 374
Connected capabilityNo374 / 374

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21811054915.208.10174002.35EPA 4575282
5TXCC005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21811054715.208.10171002.33EPA 4575284
5TXCC005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811054615.208.10174002.31EPA 4575285
5TXCC005AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21811054515.208.00172002.32EPA 4575286
5TXCC005AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21811054415.208.00172002.32EPA 4575287
5TXCC005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21811054315.208.10174002.30EPA 4575288
5TXCC005AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811054115.208.10171002.33EPA 4575289
5TXCC005AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811054015.208.10173002.30EPA 4575290
5TXCC005AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21811053915.208.10171002.33EPA 4575291
5TXCC005AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811053815.208.10173002.30EPA 4575292
5TXCC005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811053715.208.10170002.31EPA 4575293
5TXCC005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811053615.208.10170002.32EPA 4575294
5TXCC005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21811053515.208.10174002.30EPA 4575295
5TXCC005AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21811053415.208.10174002.30EPA 4575296
5TXCC005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811053315.208.10174002.31EPA 4575297
5TXCC005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811053215.208.10174002.31EPA 4575298
5TXCC005AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21811053115.208.10174002.30EPA 4575299
5TXCC005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811052915.208.10169002.35EPA 4575300
5TXCC005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811052815.208.10174002.31EPA 4575301
5TXCC005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811052715.208.10170002.33EPA 4575302

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.